General information

HOOD EXHAUST

NOTE: Read these next two pages only if you plan to vent your exhaust to the outside.
If you plan to recirculate the air back into the room, proceed to page 11.
OUTSIDE TOP EXHAUST (EXAMPLE ONLY)
The following chart describes an example of one possible ductwork installation.
Equivalent lengths of duct pieces are based on
actual tests and reflect requirements for good venting
performance with any vent hood.
* IMPORTANT: If a rectangular-to-round transition adaptor is used, the bottom corners of the damper
will have to be cut to fit, using the tin snips, in order to allow free movement of the damper.
OUTSIDE BACK EXHAUST (EXAMPLE ONLY)
The following chart describes an example of one possible ductwork installation.
Equivalent lengths of duct pieces are based on
actual tests and reflect requirements for good venting
performance with any vent hood.
NOTE: For back exhaust, care should be taken to align exhaust with space between studs, or wall should be prepared
at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
DE68-03587B-EN.indd 4
DUCT PIECES
Roof Cap
12 Ft. Straight Duct
(6" Round)
Rectangular-to-Round
Transition Adaptor*
DUCT PIECES
Wall Cap
3 Ft. Straight Duct
(3¼" x 10"
Rectangular)
90° Elbow
EQUIVALENT
NUMBER
x
LENGTH
USED
24 ft.
x
(1)
12 ft.
x
(1)
5 ft.
x
(1)
Total
Length
EQUIVALENT
NUMBER
x
LENGTH
USED
40 ft.
x
(1)
3 ft.
x
(1)
10 ft.
x
(2)
Total
Length
4
EQUIVALENT
=
LENGTH
=
24 ft.
=
12 ft.
=
5 ft.
=
41 ft.
EQUIVALENT
=
LENGTH
=
40 ft.
=
3 ft.
=
20 ft.
=
63 ft.