Hood Exhaust - Samsung ME21R7051SS Installation Instructions Manual

Over the range microwave oven
Hide thumbs Also See for ME21R7051SS:
Table of Contents

Advertisement

General information

HOOD EXHAUST

NOTE: Read these next two pages only if you plan to vent your exhaust to the outside. If you plan to
recirculate the air back into the room, proceed to page 11.
OUTSIDE TOP EXHAUST (EXAMPLE ONLY)
The following chart contains an example of one possible ductwork installation.
DUCT PIECES
Roof Cap
12 Ft. Straight Duct
(6" Round)
Rectangular-to-
Round Transition
Adaptor*
Equivalent lengths of duct pieces are based on actual tests
and reflect requirements for good venting performance with
any vent hood.
* IMPORTANT: If a rectangular-to-round transition adaptor is used, the bottom corners of the damper will have to be
cut to fit, using the tin snips, in order to allow free movement of the damper.
OUTSIDE BACK EXHAUST (EXAMPLE ONLY)
The following chart contains an example of one possible ductwork installation.
DUCT PIECES
Wall Cap
3 Ft. Straight Duct (3 ¼"
x 10" Rectangular)
90 ° Elbow
Equivalent lengths of duct pieces are based on actual tests
and reflect requirements for good venting performance with
any vent hood.
NOTE: For back exhaust, care should be taken to align the exhaust with the space between studs, or the wall should
be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
ME16H702SEB_AA_DE68-00000A-00_EN.indd 4
EQUIVALENT
NUMBER
x
LENGTH
USED
24 ft.
x
12 ft.
x
5 ft.
x
Total Length
EQUIVALENT
NUMBER
x
LENGTH
40 ft.
x
3 ft.
x
10 ft.
x
Total Length
4
EQUIVALENT
=
LENGTH
(1)
=
24 ft.
(1)
=
12 ft.
(1)
=
5 ft.
=
41 ft.
EQUIVALENT
=
USED
LENGTH
(1)
=
40 ft.
(1)
=
3 ft.
(2)
=
20 ft.
=
63 ft.
2019-03-06
4:25:16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Me21r7051sgMe19r7041fsMe19r7041fgMe19r7041ft

Table of Contents