Product Introduction
Your Wireless Bathroom Alarm includes everything you need for an emergency
bathroom alarm. The product can be set up as a stand-alone solution, or you
can configure signals to be received by central monitoring equipment in a
larger building management system.
The indication light can be battery operated, or a power lead is included to
allow connection with a central power supply.
The call/reset point included with your purchase is waterproof to IP65 and is
suitable for use in a shower area. If separate call & reset buttons are required
these are available from Rondish upon request. Additional call points or sensor
devices can be paired with the indication light, up to a maximum of 15.
Potential applications include hospitals, schools, elderly homes, hotels,
government offices, and anywhere else an alarm is required to be installed in
toilet or shower areas.
This product was designed to conform with BS 8300-2:2018
Operation
Bathroom
To raise an alarm – press the CALL button on the WCP-11. A reassurance LED
on the button will stay on while transmitting.
To reset an alarm – press the RESET button on the WCP-11. The ILB-21 can
also be done by touching a magnet to the blue dot on the front of the light, or
pressing the PROGRAM button on the back.
Advanced
Pause – if a bed monitor unit with a pause button has been paired with the ILB-
21, alarms from passive sensors can be disabled to allow a caregiver to attend a
patient without triggering any alarms. This will prevent any bed sensorpads,
floor mat sensors, motion sensors or door sensors from alarming while a
caregiver moves about a patient room. Call buttons will continue to function.
System Setup
Step 1: Power the light – Insert 6 x
C-type alkaline batteries into the
ILB-21. A lead is also provided to
connect with a 12V power source if
the alarm will be frequently used.
Step 2: Select settings – Remove
front lens using a 2mm flat-head
screwdriver and select light
settings. The dip switches control
whether the ILB-21 will forward
alarms to a central monitor unit or
as a night light. The buzzer volume
is adjustable from 89-108dB.
Switch 1 – far left: Call Forward (On/Off)
Controls whether alarms from paired devices are forwarded to
Nexus
Includes WCP-03, WCP-11, TXP-11 and DMS-02
Switch 2 – left center: Signal Bump (On/Off)
Controls whether signals unpaired devices are forwarded to Nexus
Includes TXP-11 and bed monitors
Switch 3 – right center: Group Reset (On/Off)
When set to On position, a reset button will clear alarms from any
device paired with the ILB-21.
Switch 4 – far right: Alternating Lights (On/Off)
Controls whether lights alternate when in alarm state

Advertisement

loading
Need help?

Need help?

Do you have a question about the ILB-21 and is the answer not in the manual?

Questions and answers

Summary of Contents for Rondish ILB-21

  • Page 1 Switch 3 – right center: Group Reset (On/Off) To reset an alarm – press the RESET button on the WCP-11. The ILB-21 can  When set to On position, a reset button will clear alarms from any also be done by touching a magnet to the blue dot on the front of the light, or device paired with the ILB-21.
  • Page 2 Note that this will remove all paired devices from the memory, so you will need to re-pair any devices that will continue to be used. Low battery – The ILB-21 has a red LED indication inside the white section of the light, which will blink and beep when low battery is detected. The assurance LED on the WCP-11 will blink once every 5s when low battery is detected.

This manual is also suitable for:

Wcp-11