Open Energy for All Single-phase Microinverter USER MANUAL HMS-600W-2T HMS-700W-2T HMS-800W-2T HMS-900W-2T HMS-1000W-2T Region: Europe V202308 hoymiles.com...
Page 2
However, the content of this manual is continually reviewed and amended, due to product enhancements or feedback from real-world usage. Hoymiles retains the right to modify this manual without prior notice at any time. Please refer to Hoymiles' official website at www.hoymiles.com...
Page 3
The following documents have been produced to assist you in maximizing the microinverter's potential. Datasheet Datasheet_HMS-1000W Series_EU_EN Quick Installation Guide Quick Installation Guide_HMS-1000W Series_EU_EN Installation Video_HMS-1000W Series_Global_EN Tutorial Videos Hoymiles Compatibility Calculator Others Download the Application Download and install the S-Miles Installer application before use. Revision History Issues 01 (2023-07) V1.0 2023-07-15...
• Only use the microinverter when all technical parameters are observed and applied correctly. • Hoymiles holds no liability for any damage resulting from incorrect or improper operation. Maintenance & Repair • All repairs must be done with qualified spare parts which must be installed in accordance with their intended use and by a licensed contractor or authorized Hoymiles service representative.
Page 7
Disconnect the power supply before any maintenance and repair operation. • Repairs on equipment may only be carried out by Hoymiles Service Team, by a repair team autho- rized by Hoymiels, or by authorized personnel who are thoroughly acquainted with all the warnings and operating procedures contained in this manual.
3. Product Information 3.1 Overview Functions Hoymiles HMS-1000W series microinverters are single-phase units designed for module-level operation. They convert DC power generated by PV modules into AC power, and feed the electricity into the power grid. Harnessing the power of two independent MPPT technologies, the HMS-1000W series microinverters maximize energy yield while ensuring system reliability.
Given the complexity of balcony installations, consider handrail stability, handrail weight limitations, appropriate mounting methods, and balcony regulations. Seek professional advice if necessary. Single-Microinverter System Hoymiles offers two options for building a single-microinverter system: • Field-Connected Plug Configuration: The second option utilizes a field connection plug. To implement this configuration, prepare an HMS Field Connector and an AC cable with a Schuko Plug.
Page 22
Use the HMS Connection Cable to connect the adjacent HMS Trunk Connectors. Listen for a click as they engage. Click Rooftop Obstacle Senario If your microinverters are installed too far apart, Hoymiles offers two solutions: • Use a longer HMS Connection Cable •...
Page 23
Single-phase Microinverter HMS-600W/700W/800W/900W/1000W-2T AC Side Electrical Installation a. Using a longer HMS Connection Cable: Hoymiles offers various cable lengths including 1.1m, 2.3 m, and 4.6 m. If you require a different length, contact Hoymiles sales. b. Using an HMS Extension Connector: the HMS Extension Connector can connect two HMS Connection Cables while it's not typically required.
To enable remote access, you need to connect the microinverter to the S-Miles cloud platform using a router. You can log in to your Hoymiles account on the S-Miles Installer app or S-Miles Cloud Platform, create an online power plant, and add the microinverter by scanning its SN code.
Notice: Each microinverter has been initially set with a unique AP password, which is printed on a non-removable label affixed to the right side of the microinverter’s silver-colored cover. Upon receiving the microinverter, Hoymiles recommends you modify the initial AP password following the provided steps.
1. Check if the grid configuration parameter is correct and upgrade again. Grid configuration parameter error 2. If the fault still exists, contact your dealer or Hoymiles technical support. 1. If the alarm occurs accidentally and the microinverter can still work normally, no special treatment is required.
Page 33
If no, contact the local power operator or change the grid frequency change rate limit via the Hoymiles monitoring system with the consent of the local power operator. Grid Power grid outage Please check whether there is a power grid outage.
The microinverter is powered by the DC side. If the LED light is not on, check the DC side connection. • If the connection and input voltage are normal, contact your dealer or Hoymiles technical support team for further assistance. •...
Install the replacement unit. ( See Replace the microinverter in the monitoring platform. - Log in to the S-Miles Cloud at https://world.hoymiles.com. - Navigate to O&M > Micro > Search, find the device that you want to replace, and then click the Device Maintenance icon.
Ensure the PV module’s maximum open circuit voltage is within the microinverter’s operating voltage range. • Hoymiles recommends the maximum current rating at MPP to be equal to or lower than the maximum input DC current. 2. PV module output DC power must not exceed 1.35 times the microinverter’s output AC power. See “Hoymiles Warranty Terms &...
Need help?