JA-150P Wireless PIR motion detector

The JA-150P product is a component of the JABLOTRON 100 system.
It detects of human movement in building interiors. Its detection characteristics can
be modified by using an alternative lens. False alarm immunity is available in two
levels. The detector has a pulse reaction (only reports its triggering), uses wireless
communication and is powered with two alkaline batteries. The detector should be
installed by a trained technician with a valid certificate issued by an authorized
distributor.
Installation
The detector can be installed onto a wall or in the corner of the room. There
should be no objects which quickly change temperature (electric heaters, gas
appliances, etc.) or which move (e.g. curtains hanging above a radiator) or pets
in the detector's field of sight. It is not recommended to install the detector opposite
windows or floodlights or in places with over-intense air circulation (close
to ventilators, heat sources, air conditioning outlets, non-airtight doors, etc.).
There should be no obstacles in front of the detector which might obstruct its view.
II.
I.
Figure: 1 – holes for installing on a flat wall; 2, 4 – holes for installing
at an angle (in a corner); 3 – PCB tab; 5 – cover tab
1.
Open the detector cover (by pushing the tab 5). Avoid touching the PIR
sensor inside (11) – you could damage it.
Take out the PCB – it is held by a tab (3).
2.
3.
Punch through the holes for the screws in the plastic base and attach
it on the wall. The recommended detector installation height is 2.5 m above
the floor.
4.
Set the Immunity jumper (8) as required – see the detector settings.
Insert the PCB back and proceed further according to the control panel
5.
installation manual. Basic procedure:
a.
There must be a JA-11xR radio module installed in the control panel.
Go to the F-Link program, select the required position in the Devices
b.
window and launch the enrollment mode by clicking on the Enroll option.
c.
Insert the batteries (mind the correct polarity). When the second battery
has been inserted into the detector, an enrollment signal is transmitted
to the control panel and the detector is enrolled to the selected position.
This is followed by up to three minute detector stabilization phase
indicated with LED indicator flashing.
6.
Close the detector cover. In order to comply with norms, the cover tab
(4) must be secured with the supplied screw.
1400- 00- 0000- 0001
Figure: 6 – red detector activation indicator; 7 – battery; 8 – immunity setting
jumper; 9 – production code; 10 – tamper contact; 11 – PIR sensor;
Note:
The detector can also be enrolled into the system by entering its
production code (9) in the F-Link program (or using a bar code scanner).
Detector settings
Immunity level can be set with a jumper on a PCB inside the detector and
it determines false alarm immunity. The NORM level (default setting) combines
basic immunity with a rapid reaction. The HIGH level provides increased immunity
but the detector reaction is slower.
Detector function modes
The detector can work in two modes:
Smartwatch is a default setting intended for the permanent monitoring
of movement in the guarded area. If permanent movement is detected, three
reports are sent every 20 s. The next report is then sent after 2 minutes.
JA-150P Wireless PIR motion detector
3
1
4
2
5
6
7
8
9
10
11
If the detector does not detect any movement for 10 minutes, the mode with three
reports every 20 s is used again.
The other available detector mode is one minute interval. When the detector
detects movement, it sends a report and goes into standby mode for 1 minute.
When the time is over, the detector wakes-up and remains active until the next
detection of movement.
To change the mode, press and hold the tamper contact in the cover, insert the
battery and release the tamper contact 3–5 seconds after the battery insertion.
The detector then flashes either once (smartwatch) or twice (one minute interval)
to indicate the currently selected mode.
Detector testing
When you close the detector cover, its LED indicates all movement for
a period of 15 minutes and reports it to the control panel. After this time
the detector switches to the mode which was selected during the battery insertion.
Detector function can also be checked via the Diagnostics window in the F-Link
program.
Battery replacement
The system sends a report automatically when the battery is low. Batteries
should be replaced within one week. Remember to switch the system to Service
mode before changing the batteries (otherwise a tamper alarm will be triggered).
Detection characteristics
The standard lens that is supplied with the JA-110P detector covers an area
of 110 degrees/12 m. The area is covered by 3 beams – see the following figure.
This detection characteristic is valid for standard PIR immunity.
The characteristic can be changed by using an alternative lens:
Coridor lens Designed for long corridors – with a working
JS-7904
range of up to 20 m
Increased analysis cannot be used with such a lens!
Pet lens Equipped only with the upper beam covering 120
JS-7910
degrees/12 m and not covering the floor (can eliminate
the movement of small pets on the floor)
Vertical curtain lens It does not cover an area but creates
JS-7902
a detection wall (can be used to create a barrier and report its
breach)
Note: when a lens is replaced with a different type, test whether the detector
covers the area correctly (a wrongly installed lens can cause detection errors).
Technical specifications
Power
Typical lifetime of batteries
(the longest lifetime is achieved in smartwatch mode)
LowBatt state
Quiescent current consumption
Maximum current consumption
Communication frequency
Communication range
Recommended installation height
Detection angle / detection coverage
Dimensions
Weight (without batteries)
Classification
Operational environment
Operating temperature range
Average operating humidity
Certification body
Complies with
EN 50131-6, ETSI EN 300 220-1,-2, EN 50130-4, EN 55032,
Can be operated according to ERC/REC 70-03
JABLOTRON ALARMS a.s. hereby declares that the JA-150P product
is in a compliance with the relevant Union harmonisation legislation: Directives
No: 2014/53/EU, 2014/35/EU, 2014/30/EU, 2011/65/EU if it is used
as intended. . The original of the conformity assessment can be found
at
www.jablotron.com
Note: Although this product does not contain any harmful materials we suggest
you return the product to the dealer or directly to the producer after use.
1 / 1
2x Alkaline battery, type LR6 (AA) 1.5 V
Please note: Batteries are not included
about 2 years
868.1 MHz, JABLOTRON protocol
approx. 300 m (unrestricted area)
2.5 m above the floor
110 degrees/12 m (with standard lens)
60 x 95 x 55 mm
Security grade 2 / Environmental class II
(according to EN 50131-1)
Indoor general
-10 °C to +40 °C
75 % RH, without condensation
Trezor Test s.r.o. (no. 3025), Telefication B.V.
EN 50131-1, EN 50131-2-2, EN 50131-5-3,
EN 62368-1, EN 50581, T 031
- Section Downloads.
MMB51107
< 2,2 V
15 μA
50 mA
80 g

Advertisement