Download Print this page

Washify MOXA Installing page 19

Controller integration
Hide thumbs Also See for MOXA:

Advertisement

Method 1: ICS Controller Holds Queue. Washify does not handle wash queue.
Washify sends wash command to ICS and stacks Wash immediately after transaction is completed in
Washify / gate is opened.
Roller will be activated by the ICS controller VIA a tire switch / treadle, an attendant pressing the "roller"
button on the ICS 16 Keypad", or an attendant calling a roller manually. Use this method if you will be
using a tire switch to call rollers / dollies.
Set the Mode in ICS to K for Keypad
Set the Stack setting to Y for Yes
DO NOT USE THIS METHOD IF YOU HAVE THE WATERPROOF LOADER STATION FROM WASHIFY.
Written List of Connections.
Adapter Terminal 3 connected to Integration box Relay 3 Normally Open
Adapter Terminal 4 connected to Integration box Relay 4 Normally Open
Adapter Terminal 5 connected to Integration box Relay 5 Normally Open
Adapter Terminal 6 connected to Integration box Relay 6 Normally Open
Adapter Terminal 7 connected to Integration box Relay 7 Normally Open
Adapter Terminal 8 connected to Integration box Relay 8 Normally Open
Adapter Terminal 9 connected to Integration box Relay 9 Normally Open
Adapter Terminal 10 connected to Integration box Relay 10 Normally Open
Adapter Terminal 11 connected to Integration box Relay 11 Normally Open
Integration Box Relay 11 Normally Open Jumped to Integration Box Relay 16 Normally Open
Integration Box Relay 8 Normally Open Jumped to Integration Box Relay 16 Common
The purpose of the last 2 connections that are jumps inside the integration box is to allow washify to
control the "Sale" button on ICS with 1 relay (Relay 16).
Method 2: This method will utilize the Wash Queue in the Washify software. ICS will not be in stacking
mode. This method will not work with a Tire Switch / Treadle. Use this mode if you do not wish to stack
on ICS and want to send the wash and roller with a button press on washify.
Mode in ICS must be set to K for Keypad
Stacking in the ICS settings must be N for No.
Autoroller must be set to No.
Written List of Connections.
Adapter Terminal 3 connected to Integration box Relay 3 Normally Open
Adapter Terminal 4 connected to Integration box Relay 4 Normally Open
Adapter Terminal 5 connected to Integration box Relay 5 Normally Open
Adapter Terminal 6 connected to Integration box Relay 6 Normally Open
Adapter Terminal 7 connected to Integration box Relay 7 Normally Open