Electrical Data; Typical Field Power Wiring Diagram - York BUZ024 Installation Manual

Table of Contents

Advertisement

268723-BIM-C-0908
Figure 8: Typical Field Power Wiring Diagram
Table 5: Electrical Data
Compressors
Size
(each)
Volt
(Tons)
RLA LRA MCC
024
208/230-1-60 12.8 60
(2.0)
208/230-1-60 14.7 73
030
(2.5)
208/230-3-60 10.4 60
460-3-60
4.5
31
208/230-1-60 15.4 83
036
(3.0)
208/230-3-60 11.5 77
460-3-60
5.1
35
208/230-1-60 18.6 105
042
(3.5)
208/230-3-60 13.4 88
460-3-60
6.4
39
208/230-1-60 21.1 113
048
208/230-3-60 16.0 120
(4.0)
460-3-60
8.3
60
10
OD Fan
Supply
Motors
Blower
(each)
Motor
FLA
FLA
Model
None
2NH04500506
20
1.2
4.1
2NH04500706 5.6 / 7.5
2NH04501006 7.5 / 10
None
2NH04500506
23
1.2
4.1
2NH04500706 5.6 / 7.5
2NH04501006 7.5 / 10
2NH04501506 11.3 / 15
None
16
0.8
4.1
2NH04501025 7.5 / 10
2NH04501525 11.3 / 15
None
7
0.8
2.1
2NH04501046
2NH04501546
None
2NH04500506
24
1.2
6.0
2NH04500706 5.6 / 7.5
2NH04501006 7.5 / 10
2NH04501506 11.3 / 15
None
18
1.2
6.0
2NH04501025 7.5 / 10
2NH04501525 11.3 / 15
None
8
0.8
3.0
2NH04501046
2NH04501546
None
2NP04501006 7.5 / 10
29
1.2
6.0
2NP04501506 11.3 / 15
2ND04501506
None
21
1.2
6.0
2NP04501025 7.5 / 10
2NP04501525 11.3 / 15
None
10
0.8
3.0
2NP04501046
2NP04501546
None
2NP04501006 7.5 / 10
33
1.2
6.0
2NP04501506 11.3 / 15
2NP04502006
2NP04502506 18.8 / 25
None
2NP04501025 7.5 / 10
25
1.2
6.0
2NP04501525 11.3 / 15
2NP04502025
2NP04502525 18.8 / 25
None
2NP04501046
13
0.8
3.0
2NP04501546
2NP04502046
2NP04502546
Electric Heat Option
kW
Stages
Amps
-
-
-
3.8 / 5
1
18.1 / 20.8
2
27.1 / 31.3
2
36.1 / 41.7
-
-
-
3.8 / 5
1
18.1 / 20.8
2
27.1 / 31.3
2
36.1 / 41.7
2
54.2 / 62.5
-
-
-
1
20.8 / 24.1
1
31.3 / 36.1
-
-
-
10
1
12
15
1
18
-
-
-
3.8 / 5
1
18.1 / 20.8
2
27.1 / 31.3
2
36.1 / 41.7
2
54.2 / 62.5
-
-
-
1
20.8 / 24.1
1
31.3 / 36.1
-
-
-
10
1
12
15
1
18
-
-
-
2
36.1 / 41.7
2
54.2 / 62.5
3.8 / 5
1
18.1 / 20.8
7.5 / 10
1
36.1 / 41.7
-
-
-
1
20.8 / 24.1
1
31.3 / 36.1
-
-
-
10
1
12
15
1
18
-
-
-
2
36.1 / 41.7
2
54.2 / 62.5 101.3 / 111.7
15 / 20
2
72.2 / 83.3 123.9 / 137.7
2
90.3 / 104.2 146.4 / 163.8
-
-
-
1
20.8 / 24.1
1
31.3 / 36.1
15 / 20
2
41.7 / 48.1
2
52.1 / 60.1
-
-
-
10
1
12
15
1
18
20
2
24.1
25
2
30.1
2
Max Fuse
/
1
MCA
3
Breaker
Size
(Amps)
(Amps)
21.3
30
43.9 / 47.3
50 / 50
55.2 / 60.4
60 / 70
66.4 / 73.4
70 / 80
23.7
30
46.2 / 49.7
50 / 50
57.5 / 62.7
60 / 70
68.8 / 75.8
70 / 80
91.4 / 101.8
100 / 110
18.3
25
44.4 / 48.4
45 / 50
57.4 / 63.4
60 / 70
8.5
15
23.5
25
31
35
26.5
35
49 / 52.5
50 / 60
60.3 / 65.5
70 / 70
71.6 / 78.5
80 / 80
94.2 / 104.6
100 / 110
21.6
30
47.6 / 51.6
50 / 60
60.7 / 66.7
70 / 70
10.1
15
25.2
30
32.7
35
30.5
40
75.6 / 82.5
80 / 90
98.2 / 108.6
100 / 110
53 / 56.5
60 / 60
75.6 / 82.5
80 / 90
24
30
50 / 54
60 / 60
63 / 69.1
70 / 70
11.8
15
26.8
30
34.3
35
33.6
45
78.7 / 85.7
90 / 90
110 / 125
125 / 150
150 / 175
27.2
35
53.3 / 57.3
60 / 60
66.3 / 72.3
70 / 80
79.3 / 87.3
80 / 90
92.4 / 102.4
100 / 110
14.1
20
29.2
30
36.7
40
44.2
45
51.8
60