Download Print this page

Hitachi RAS-FSXNSE Series Instruction Manual page 25

Advertisement

Available languages

Available languages

COMBINATION OF OUTDOOR UNITS
3.2 ComBination of oUtDoor Units fsXnPe
The power range of the RAS-(5-72)FSXNPE outdoor units is obtained by applying one unit (RAS-(5-18)FSXNPE) or by the
combination of two, three or four outdoor units (RAS-(20-72)FSXNPE), depending on the instructions in the following tables.

Base units
HP
model
RAS-5FSXNPE
HP
model
RAS-12FSXNPE

Combination of base units
HP
model
ras-20fsXnPe
RAS-10FSXNPE
Combination
RAS-10FSXNPE
HP
model
ras-30fsXnPe
Combination
RAS-18FSXNPE
RAS-12FSXNPE
HP
model
ras-40fsXnPe
RAS-14FSXNPE
Combination
RAS-14FSXNPE
RAS-12FSXNPE
HP
model
ras-50fsXnPe
RAS-18FSXNPE
Combination
RAS-18FSXNPE
RAS-14FSXNPE
Combinations of base units only for Heat Pump system (*)
HP
model
ras-56fsXnPe
RAS-18FSXNPE
RAS-14FSXNPE
Combination
RAS-12FSXNPE
RAS-12FSXNPE
HP
66
model
ras-66fsXnPe
RAS-18FSXNPE
RAS-16FSXNPE
Combination
RAS-16FSXNPE
RAS-16FSXNPE
3
PMML0479 rev.4 - 11/2018
5
6
RAS-6FSXNPE
12
14
RAS-14FSXNPE
20
22
ras-22fsXnPe
RAS-12FSXNPE
RAS-10FSXNPE
30
32
ras-32fsXnPe
-
-
RAS-18FSXNPE
RAS-14FSXNPE
40
42
ras-42fsXnPe
RAS-14FSXNPE
RAS-14FSXNPE
RAS-14FSXNPE
50
52
ras-52fsXnPe
RAS-18FSXNPE
RAS-18FSXNPE
RAS-16FSXNPE
56
58
ras-58fsXnPe
RAS-18FSXNPE
RAS-14FSXNPE
RAS-14FSXNPE
RAS-12FSXNPE
68
70
ras-68fsXnPe
ras-70fsXnPe
RAS-18FSXNPE
RAS-18FSXNPE
RAS-18FSXNPE
RAS-18FSXNPE
RAS-16FSXNPE
RAS-18FSXNPE
RAS-16FSXNPE
RAS-16FSXNPE
8
RAS-8FSXNPE
RAS-10FSXNPE
16
RAS-16FSXNPE
RAS-18FSXNPE
24
ras-24fsXnPe
ras-26fsXnPe
RAS-12FSXNPE
RAS-16FSXNPE
RAS-12FSXNPE
RAS-10FSXNPE
34
ras-34fsXnPe
ras-36fsXnPe
-
RAS-18FSXNPE
RAS-18FSXNPE
RAS-16FSXNPE
RAS-18FSXNPE
44
ras-44fsXnPe
ras-46fsXnPe
RAS-18FSXNPE
RAS-18FSXNPE
RAS-14FSXNPE
RAS-14FSXNPE
RAS-12FSXNPE
RAS-14FSXNPE
54
ras-54fsXnPe
RAS-18FSXNPE
RAS-18FSXNPE
RAS-18FSXNPE
60
ras-60fsXnPe
ras-62fsXnPe
RAS-16FSXNPE
RAS-16FSXNPE
RAS-16FSXNPE
RAS-16FSXNPE
RAS-14FSXNPE
RAS-16FSXNPE
RAS-14FSXNPE
RAS-14FSXNPE
!
72
C a U t i o n
ras-72fsXnPe
Only the combinations in the table are allowed,
RAS-18FSXNPE
not being possible to mix heat pump system (2
pipes) and heat recovery system (3 pipes) in
RAS-18FSXNPE
the same combination. It is not possible to mix
RAS-18FSXNPE
standard and high efficiency units either.
RAS-18FSXNPE
(*) DSW7 pin4 must be set OFF in all the
modules of the combination
10
18
26
28
ras-28fsXnPe
RAS-16FSXNPE
RAS-12FSXNPE
36
38
ras-38fsXnPe
-
RAS-14FSXNPE
RAS-12FSXNPE
RAS-12FSXNPE
46
48
ras-48fsXnPe
RAS-18FSXNPE
RAS-18FSXNPE
RAS-12FSXNPE
62
64
ras-64fsXnPe
RAS-16FSXNPE
RAS-16FSXNPE
RAS-16FSXNPE
RAS-16FSXNPE

Advertisement

loading