12. OPERATION
5.
Carry out bucket and arm operation for 5 minutes at full stroke, alternat-
ing between bucket operation and arm operation at 30 second intervals.
If the swing lock switch
swing control lever
can be increased earlier.
NOTICE
When the work equipment is retracted, take care that it does not
interfere with the machine body or ground.
6.
After carrying out the warming-up operation, check that each gauge
and monitor lamp is in the following condition.
Engine water temperature gauge
Fuel gauge
: Inside green range
Engine water temperature monitor
Radiator water level monitor
Engine oil pressure monitor
Charge level monitor
Fuel level monitor
Air cleaner clogging monitor
Engine pre-heating monitor
Engine oil level monitor
Hydraulic oil level monitor
7.
Check that there is no abnormal exhaust gas colour, noise, or vibra-
tion. If any abnormality is found, repair it.
8.
Press working mode switch
the mode to be used lights up.
12.3.2 IN COLD AREAS (AUTOMATIC WARMING-UP
OPERATION)
When starting the engine in cold areas, carry out the automatic
warming-up operation after starting the engine.
When the engine is started, if the engine water temperature is low
o
o
(below 30
C (86
F)), the warming-up operation is carried out automatically.
The automatic warming-up operation is cancelled if the engine water
temperature reaches the specified temperature (30
warming-up operation is continued for 10 minutes. If the engine water
temperature or hydraulic oil temperature are low after the automatic
warming-up operation, warm the engine up further as follows.
NOTICE
When the hydraulic oil is at a low temperature, do not carry out
operations or move the levers suddenly. Always carry out the
warming-up operation. This will help to extend the machine life.
Do not suddenly accelerate the engine before the warming-up
operation is completed.
Do not run the engine at low idling or high idling continuously
for more than 20 minutes. This will cause leakage of oil from the
turbocharger oil supply piping. If it is necessary to run the en-
gine at idling, apply a load from time to time or run the engine at
a mid-range speed.
1.
Set fuel control dial
engine for about 5 minutes without load.
2-54
is set to the ON (actuated) position and
is operated at full stroke, oil temperature rise
: Inside green range
: OUT
: OUT
: OUT
: OUT
: OUT
: OUT
: OUT
: OUT
: OUT
on the monitor panel until the lamp of
at the low idling (MIN) position and run the
o
o
C (86
F)) or if the
H/O
G/O
F/O
L/O
BP00100
B/O