Figure 56 5U84 Operator's Panel Fault Leds - Seagate Exos X 4006 Series Hardware Installation And Maintenance Manual

Hide thumbs Also See for Exos X 4006 Series:
Table of Contents

Advertisement

LED
Type
Module fault
Logical status
, Drawer 1 , Drawer 2
hardware fault
Drawer panel fault LEDs
Each drawer contains up to 42 drive modules in their carriers (DDICs) and retains cable connections inside the enclosure
chassis. Drawer panel fault LEDs register whether the failure is a hardware failure, a logical failure, or a cabling failure for that
drawer or its related components. The asterisk (*) indicates a fault condition.
Color
State
Status
Ops panel completing 5s test
Storage enclosure rear panel area module fault: CM, fan, or PSU when paired with
On*
module fault LED
Drive fault, when paired with drive fault LED
Amber
Unknown, invalid, or mixed module type, such as drive or PSU
Flashing*
VPD configuration error or 1²C bus failure
Off
Storage enclosure rear panel area modules functioning properly
System component hardware fault: drive, cable, or fanout card
On*
System component hardware change of status
Drive fault caused loss of redundancy
Amber
Flashing* System software reports an informational condition for the array, such as a rebuild
operation, with corresponding drives registering a fault condition
Off
System component hardware functioning properly
On*
Upper, lower drawer hardware fault: drive, cable, or fanout card
Amber
Flashing* Unit ID (UID) or locate is active for Drawer 1, Drawer 2 sideplane or drive
Off
Upper, lower drawer hardware functioning properly

Figure 56 5U84 operator's panel fault LEDs

Chapter 9   Hardware installation and configuration issues
80

Advertisement