INSTALLATION INSTRUCTIONS FOR
ALPACO ELEGANCE PARTITIONS
160 Tower Drive, Burr Ridge, IL 60527
Phone: (708) 442-6800
Fax: (708) 442-7439
www.asi-accuratepartitions.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the ALPACO ELEGANCE and is the answer not in the manual?

Questions and answers

Summary of Contents for ASI ALPACO ELEGANCE

  • Page 1 INSTALLATION INSTRUCTIONS FOR ALPACO ELEGANCE PARTITIONS 160 Tower Drive, Burr Ridge, IL 60527 Phone: (708) 442-6800 Fax: (708) 442-7439 www.asi-accuratepartitions.com...
  • Page 2 ALPACO ELEGANCE INSTALLATION Table of Contents Topic Page Layout and Wall Brackets……………………………………………………… Panel and Pilaster Prep…………………………………………………………. Securing Components and Headrail …………………………………………… Panel to Pilaster/Wall Assembly …………………..………...………………… Pilaster/Wall Assembly ………….……….………...…………..……………… Pilaster/Panel Alcove Assembly………...………….…………………………. Door Hardware Inswing Assembly……………..........Door Hardware Outswing Assembly…………………………………………..
  • Page 3 Panel Center Line backings of the walls and floor are adequate to support the secure mounting of the ALPACO Elegance units. B. Review the layout drawings and package lists that have accompanied this order. C. Establish and mark panel center lines for wall brackets.
  • Page 4 ALPACO ELEGANCE INSTALLATION STEP 3: FIGURE 3 POSITION PANEL A. Assemble pedestal and adjust it to the desired height. B. Place the panel on a temporary support device that is 6” (9” if required) tall. Set the panel into the wall bracket and unanchored pedestal.
  • Page 5 ALPACO ELEGANCE INSTALLATION STEP 5: FIGURE 5 SECURING PILASTERS TO PANELS A. A 6” (or 9” if required) support is recommended to place under each pilaster to assist in alignment. B. Plumb each pilaster and fasten the pilaster to the panel with U-brackets using through-bolts through the panel.
  • Page 6 ALPACO ELEGANCE INSTALLATION PANEL TO PILASTER/WALL HARDWARE LIST ASSEMBLY PICTURE DESCRIPTION A. Plumb panel and fasten panel to wall bracket #10-24 x 3/8” NUT with through-bolts. To facilitate the through- #10-24 x 1/2" BOLT bolts, the holes of the panel should be drilled with a 1/4”...
  • Page 7 ALPACO ELEGANCE INSTALLATION PILASTER/WALL HARDWARE LIST ASSEMBLY PICTURE DESCRIPTION #12 x 2.5" WALL A. Verify that the pilasters are both plumb and SCREW level before continuing. RED PLASTIC SHIELD B. Fasten pilaster to wall bracket using "U" BRACKET through-bolts. #10-24 x 3/8” NUT #10-24 x 1/2"...
  • Page 8 ALPACO ELEGANCE INSTALLATION PILASTER/ PANEL ALCOVE HARDWARE LIST ASSEMBLY PICTURE DESCRIPTION Note: For door details, see pages 8 and 9. ALCOVE BRACKET #10-24 x 3/8” NUT #10-24 x 1/2" BOLT #12 x 2.5" WALL SCREW RED PLASTIC SHIELD "U" BRACKET...
  • Page 9 ALPACO ELEGANCE INSTALLATION DOOR HARDWARE HARDWARE LIST ASSEMBLY - INSWING PICTURE DESCRIPTION A. Doors with a width of at least 32” require 4 HINGE ASSEMBLY hinges. WITH COVER PLATE (CAMMED) B. Cams are preset at an angle of 0°. Adjust this angle as desired.
  • Page 10 ALPACO ELEGANCE INSTALLATION DOOR HARDWARE HARDWARE LIST ASSEMBLY - OUTSWING PICTURE DESCRIPTION A. Doors with a width of at least 32” require 4 HINGE ASSEMBLY hinges. WITH COVER PLATE (CAMMED) B. Cams are preset at an angle of 0°. Adjust this angle as desired.
  • Page 11 ALPACO ELEGANCE INSTALLATION URINAL SCREEN HARDWARE LIST ASSEMBLY PICTURE DESCRIPTION A. Before proceeding, confirm that the backing of the wall is adequate to support the #12 x 2.5" WALL SCREW mounting of urinal screens. Check shop drawings for layout. RED PLASTIC SHIELD B.
  • Page 12 ALPACO ELEGANCE INSTALLATION LATCH HARDWARE LIST ASSEMBLY PICTURE DESCRIPTION INDICATOR COVER WITH INSERT CENTER SHAFT INDICATOR DIAL INDICATOR DIAL PLACEMENT SLEEVE LATCH HANDLE #10-24 x 3/8” NUT #10-24 x 1/2" BOLT Page 11 160 Tower Drive, Burr Ridge, IL 60527...
  • Page 13 ALPACO ELEGANCE INSTALLATION CARE AND MAINTENANCE OF BATHROOM PARTITIONS In order to provide bathroom partitions with proper care and maintenance, the following instructions must be followed: A. All surfaces must be kept clean with water and a mild soap solution only.