Operation; Menu Settings - Bell MF4600 Series User Manual

Mems mass flow meter

Advertisement

SIARGO

Operation

The meter shall display instant, accumulated and
peak-valley flowerate. The indication light shall be
lighted accordingly. Please see the detailed
description below.
Instant flowrate display
1. Instant flowrate is a default display mode, both
2. Instant flowrate is displayed by 4
LED
3. When the instant flowrate is over the allowed range, I-
min) will be flashing.
4. If I-
LED
and -
II LED
flash at the same time, it indicates that the actual flowrate is over the
calibrated range or the display value is incorrect.
Accumulated flowrate display
1. The accumulated flowrate is displayed by 8 digits that is separated with two 4 digit
display where I-
LED
indicates the first 4 digits and -
units is
SL
.
2. The accumulated flowrate can be reset via the keyboard.
NOTE The flow accumulation will be saved every 3 minutes. For instance:
:
Ÿ
The flow accumulation will not be saved if power off @ 2 minutes.
Ÿ
The flow accumulation will be the value of 33 minutes if power off @ 34 minutes.
Peak-Valley flowrate retrieval
1. The data of the last registered peak-valley flowrate can be retrieved via the keyboard.
2. When the peak flowrate value is displayed and flashed, the I-
3. When the valley flowrate value is displayed and flashed, the -
User Manual
Operation Mode
I-LED on
II-LED on
Push
Peak flowrate
(LED flashing)
/
Push
and keep for
more than 2sec
Push
Power
Instant Flow
on
Rate
Fn
/
Push
Acc. Flowrate
st
1
4digits
(LED on)
I-LED on
II-LED on
LED
(I and ) will be off.
II
digit with a decimal, the unit is
SLPM
LED
(over max) or -
II LED
II LED
indicates the last 4 digits. The
LED
will light.
II LED
will light.
SIARGO

Menu settings

The Menu Settings will allow the user to execute keyboard lock/unlock, reset accumulated
flowrate, reset offset, set time, response time, instant flow decimal point etc.
Valley flowrate
(LED flashing)
Keyboard lock
This function shall prevent unintended changes of the parameters by press the keyboard.
When keyboard is locked, the menu function is disabled.
Accumulated flowrate reset
Acc. Flowrate
This function shall reset the accumulated flowrate, and the meter will re-start from null.
last 4digits
(LED on)
Offset reset
This function shall reset the offset which may be due to drift after a certain period of
performance. It shall help for improving accuracy.
make sure there is no flow in the meter otherwise it will have impact to the accuracy.
Sampling time
(below
This function allows user to set the sampling time between analog output and digital
output via the serial port. Once the setting is done, it will be immediately effective but the
settings will only be saved into the
Display
Sampling
Display update time
This function allows the user to set the display update time of the meter. Once the setting
is done, it will be immediately effective but the settings will only be saved into the EEPROM
after switch to another function.
Display
Update
Peak-valley values reset
This function allows user to reset the peak value to null.
3
Note
: When performing offset reset,
EEPROM
after switch to another function.
4.001
4.002
4.005
4.010
4.020
10ms
20ms
50ms
100ms
200ms
5.050
5.100
5.025
500ms
250ms
1000ms
www.bellflowsystems.co.uk
User Manual
4.050
4.100
500ms 1000ms
5.200
2000ms