Configuration Procedure - H3C S5830V2 Series Configuration Manual

Hide thumbs Also See for S5830V2 Series:
Table of Contents

Advertisement

Figure 7 Network diagram
Core layer
Distribution layer
Access
layer

Configuration procedure

This section provides only TRILL-related configurations.
1.
Configure the downlink ports of access layer devices:
# Enable TRILL globally on RB 1, and enable TRILL on downlink port Ten-GigabitEthernet 1/0/1 of
RB 1.
<RB1> system-view
[RB1] trill
[RB1-trill] quit
[RB1] interface ten-gigabitethernet 1/0/1
[RB1-Ten-GigabitEthernet1/0/1] trill enable
[RB1-Ten-GigabitEthernet1/0/1] quit
# Configure RB 2 through RB 5 in the way RB 1 is configured.
2.
Configure the uplink port of access layer devices:
# Enable TRILL on uplink port Ten-GigabitEthernet 1/0/2 through Ten-GigabitEthernet 1/0/5 of
RB 1, and configure these ports as trunk ports.
[RB1] interface ten-gigabitethernet 1/0/2
[RB1-Ten-GigabitEthernet1/0/2] trill enable
[RB1-Ten-GigabitEthernet1/0/2] trill link-type trunk
[RB1-Ten-GigabitEthernet1/0/2] quit
[RB1] interface ten-gigabitethernet 1/0/3
[RB1-Ten-GigabitEthernet1/0/3] trill enable
[RB1-Ten-GigabitEthernet1/0/3] trill link-type trunk
[RB1-Ten-GigabitEthernet1/0/3] quit
[RB1] interface ten-gigabitethernet 1/0/4
[RB1-Ten-GigabitEthernet1/0/4] trill enable
[RB1-Ten-GigabitEthernet1/0/4] trill link-type trunk
[RB1-Ten-GigabitEthernet1/0/4] quit
RB 6
RB 1
RB 2
RB 7
RB 8
RB 3
18
TRILL network
RB 9
RB 4
RB 5