SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other
hazards please read all warnings and instructions.
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
Installation and service of Lowering Devices should be performed by a qualified licensed electrician and mechanical technician.
Maintenance of the Lowering Devices should be performed by person(s) familiar with the Lowering Devices construction and
operation and any hazards involved.
DO NOT INSTALL DAMAGED PRODUCT! This Lowering Device has been properly packed so that no parts should have been
damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet
in connection with installation, operation, or maintenance. Should further information be desired or should particular problems
arise which are not covered sufficiently for the purchaser's or owner's purposes, this matter should be referred to Acuity Brands
Lighting, Inc.
Disconnect or turn off power before installation or servicing.
Verify that supply voltage is correct by comparing it with the luminaire label information.
Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local
code requirements.
All wiring connections should be capped with UL approved recognized wire connectors.
Do not stand directly beneath the pole or lowering device during installation except as instructed to in this manual.
Do not depend on the lowering device cables to tether a slip-fit type pole. Failure to use a tethering cable may result in injury
or death.
Operate the lowering device only while standing at the maximum distance from the pole allowed by the twenty foot long
remote control cord. Failure to follow this procedure may result in injury or death.
Wear gloves, safety glasses, hardhats and safety shoes at all times when removing
servicing or performing maintenance.
Follow pole manufacture installation instruction.
Follow luminaire manufacture installation instruction when attaching to the lowering device.
Do not expose the torque limiter or shear pin to damaging elements or mistreatment such as sand, mud, salt spray or other
conditions which could render either safety mechanism inoperable. Do not attempt to adjust the torque limiting clutch or
replace the shear pin. If repairs are necessary, replace damaged equipment with replacement components from Holophane.
Failure to follow these warnings may result in injury or death.
For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.
Our Brands
Indoor/Outdoor
Lithonia Lighting
Carandini
Holophane
RELOC
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
RISK OF ELECTRIC SHOCK
Failure to follow any of these instructions could void product warranties.
Indoor Lighting
Gotham
Mark Architectural Lighting
Peerless
Renaissance Lighting
Winona Lighting
© 2010 Acuity Brands Lighting, Inc. All rights reserved. 6/03/13
IMPORTANT SAFETY INSTRUCTIONS
LOWERING DEVICES
WARNING
CAUTION
RISK OF INJURY
Lowering Devices
Outdoor Lighting
American Electric Lighting
Antique Street Lamps
Hydrel
Tersen
ABL General Warnings, Form No. 503.204
from carton, installing,
Controls
DARK TO LIGHT
Lighting Control & Design
ROAM
Sensor Switch
Synergy
Page 1 of 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Holophane 15 and is the answer not in the manual?

Questions and answers

Summary of Contents for Acuity Brands Lighting Holophane 15

  • Page 1 Winona Lighting Synergy Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products. © 2010 Acuity Brands Lighting, Inc. All rights reserved. 6/03/13 ABL General Warnings, Form No. 503.204...
  • Page 2 HIGH MAST 15 and 18 LOWERING DEVICES LD TYPE 15: TOP LATCHING, CENTERING ARM, PORTABLE WINCH/DRIVE MOTOR LD TYPE 18: TOP LATCHING, BUMPER, PORTABLE WINCH/DRIVE MOTOR OWNER’S MANUAL This manual must remain with the lowering device and always be available to the owner and operator.
  • Page 3 PLEASE READ THIS NOTICE A copy of this manual is to remain with the lowering device at all times. Keep it in the sealed plastic protective cover provided and store inside the pole handhole cover. Operating and maintenance personnel must read and understand completely Sections III and IV.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS Section I Lowering Device Material List Section II Assembly Instructions Section III Operating Instructions Section IV Maintenance Instructions LUBRICATION REPLACING THE WINCH CABLE PORTABLE DRIVE MOTOR SHAFT REPLACEMENT POWER CORD REPLACEMENT LUMINAIRE REMOVAL LATCH SYNCHRONIZATION ADJUSTMENT AND LATCHING Section V Attachments...
  • Page 5 High Mast SECTION I HOLOPHANE Lowering Devices LOWERING DEVICE MATERIAL LIST Assemblies Supplied With Each Device: Headframe assembly with cover (one per) Mounting ring assembly (one per) Power cord and ring junction box (one per) Clevis assembly with coiled hoisting cables (one per) Circuit breaker assembly and enclosure (one per) Luminaire mounting arms (quantity as required) Safety cable and stringing hook (one per)
  • Page 6 GR1129...
  • Page 7 High Mast SECTION II HOLOPHANE Lowering Devices ASSEMBLY INSTRUCTIONS 2.1 Pole Preparation 2.2.3 Unpack the junction box with the main power cord and place near the top of pole. Uncoil the power 2.1.1 See pole supplier or contact Holophane Cus- cord halfway down along the pole and back to the top.
  • Page 8 High Mast SECTION II HOLOPHANE Lowering Devices 2.2.9 Feed the power cord through the large center hole in the clevis approximately 2 feet, making certain it is centered in the three hoisting cables. CAUTION The power cord and cables must not be crossed or wrapped around each other.
  • Page 9 HOLOPHANE High Mast SECTION II Lowering Devices 2.4 Hoisting Cable Rigging and Adjustment GR1135 Figure 6 2.3.3 Attach two foot long lead wires (not supplied by Holophane) to the top terminals of the circuit breaker. Slide the circuit breaker assembly through the bottom of the pole and secure with the nuts and bolts provided.
  • Page 10 High Mast SECTION II HOLOPHANE Lowering Devices latch barrels. While workers hold the ring against the 2.4.5 Pull a hoisting cable just slightly tight and straight headframe, pull one of the hoisting cables as tight as out of the pipe below the latch pin. Install the adjust- possible by hand and slide the terminal fitting against ment tube onto the cable, unthreaded end first, and the adjustment tube.
  • Page 11 High Mast SECTION II HOLOPHANE Lowering Devices 2.5 Completing the Pole-top Assembly 2.5.1 If the device is equipped with a bumper ring instead of iris-type guide arms, proceed to paragraph 2.5.3. Otherwise, attach both guide arm spring brack- ets to the ring. (See Figure 13) The double washers must be installed between the brackets and the ring to avoid possible interference with the luminaire mounting brackets which will be mounted to the ring later.
  • Page 12 High Mast SECTION II HOLOPHANE Lowering Devices LUMINAIRE CONFIGURATION (TOP VIEW OF RING) JUNCTION BOX (TYP) *FAA Marker locations. Mount the FAA marker at these locations on lowering devices with 2, 3, 4, and 6 luminaires. For devices with 8, 9, or 10 luminaires, mount the FAA marker at any vacant luminaire mounting position.
  • Page 13 HOLOPHANE High Mast SECTION II Lowering Devices WARNING 2.5.7.3 Make sure all the hoisting cables and power cord are seated in their respective pulley grooves. Both the safety cable and the stringing hook must be installed during pole erection to secure the ring from the bottom of the pole.
  • Page 14 HOLOPHANE High Mast SECTION II Lowering Devices Supports for Highway Signs,Luminaires and Traffic Signals - Fifth Edition 2009 Section 5.17.5.2 anchor bolt Before wiring twistlock plug to the power cord, install the black rubber protective cover as follows; pretensioning . 1.
  • Page 15 High Mast SECTION II HOLOPHANE Lowering Devices HOOK AND HAND KNOB Figure 22 2.7.4 The portable drive motor can now be used to pull itself into the lower handhole. Rotate the switch to the GR1423 “FOR” position. The tongue of the power unit will be Figure 23 pulled toward the bottom handhole.
  • Page 16 HOLOPHANE High Mast SECTION II Lowering Devices GR1148 Figure 24 is now ready to be raised to the top of the pole. GR1150 Figure 26 2.8.3 Following the operating instructions of Section III, threaded end, DO NOT unthread down past this when raise the ring and luminaires to the top of the pole, doing adjustments.
  • Page 17 SINGLE CIRCUIT WIRING DIAGRAMS GR1165 GR1164 GR1166...
  • Page 18 DOUBLE CIRCUIT WIRING DIAGRAMS GR1168 GR1167...
  • Page 19 HOLOPHANE High Mast SECTION III Lowering Devices OPERATING INSTRUCTIONS EVERY PERSON WHO INTENDS TO OPERATE THE LOWERING DEVICE SHOULD READ COMPLETELY AND UNDERSTAND FULLY THESE INSTRUCTIONS BEFORE OPERATING THE DEVICE. 3.0 General Comments checked using a high powered flashlight. 3.0.1 The portable drive motor is provided with a twenty •...
  • Page 20 High Mast SECTION III HOLOPHANE Lowering Devices LD RING LATCH POSITION INDICATOR UNIT BEING RAISED. LATCH AT TOP OF BARREL. UNIT LOWERED INTO LATCH ENTERING BARREL. UNIT READY TO LOWER LATCHED POSITION. INTO LATCHED POSITION. CABLE IS SLACK. LATCH RAISED TO TOP OF LATCH EXISTING BARREL.
  • Page 21 High Mast SECTION III HOLOPHANE Lowering Devices 3.3.4 Connect the pigtail connector to the motor or transformer plug and turn on the circuit breaker. 3.4 Raising and Latching the LD Ring 3.4.1 Turn the remote control switch to “FOR”. As the ring nears the headframe, if the ring is not equipped with an iris-type guide arm system, the ring may be swinging about by several inches.
  • Page 22: Maintenance Instructions

    High Mast SECTION IV HOLOPHANE Lowering Devices MAINTENANCE INSTRUCTIONS 4.2.3 Attach the new cable obtained from Holophane, in 4.1 LUBRICATION the same manner that the old cable was attached. 4.1.1 Winch The winch gear housing, as received from 4.2.4 While rewinding the winch, wrap as tightly and Holophane is lubricated and sealed.
  • Page 23: Power Cord Replacement

    HOLOPHANE High Mast SECTION IV Lowering Devices 4.4.13 Disconnect the old cord from the cord clamp and junction box on the ring and cut the new cord just above the splice and thread it down through the cord clamp and 4.4 POWER CORD REPLACEMENT into the junction box.
  • Page 24 HOLOPHANE High Mast SECTION V Lowering Devices ATTACHMENTS...
  • Page 25 Acuity Lighting Group, Inc. Field Service Department P.O.Box 3004, Newark, OH 43058-3004 IM-187-E 1/13 ©2013 Acuity Brands Inc. Visit our web site at www.holophane.com Printed in USA...