Download Print this page

Advertisement

Quick Links

SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
·
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/
abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and
all fixture labels.
·
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general
precautions.
·
Installation and service of luminaires should be performed by a qualified licensed electrician.
·
Maintenance of the luminaires should be performed by person(s) familiar with the luminaires' construction and
operation and any hazards involved. Regular fixture maintenance programs are recommended.
·
It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on
ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a
solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry.
Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing
damaged gaskets as necessary.
·
DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have
been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should
be replaced.
·
Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
·
These instructions do not purport to cover all details or variations in equipment nor to provide every possible
contingency to meet in connection with installation, operation, or maintenance. Should further information
be desired or should particular problems arise which are not covered sufficiently for the purchaser's or owner's
purposes, this matter should be referred to Acuity Brands Lighting, Inc.
RISK OF ELECTRIC SHOCK
 Disconnect or turn off power before installation or
servicing.
 Verify that supply voltage is correct by comparing it with
the luminaire label information.
 Make all electrical and grounded connections in
accordance with the National Electrical Code (NEC) and
any applicable local code requirements.
 All wiring connections should be capped with UL
approved recognized wire connectors.
 Wear gloves and safety glasses at all times when
removing luminaire from carton, installing, servicing or
performing maintenance.
 Avoid direct eye exposure to the light source while it is on.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
WARNING
CAUTION
RISK OF INJURY
WARNING
RISK OF BURN
 Allow lamp/fixture to cool before handling. Do not
touch enclosure or light source.
 Do not exceed maximum wattage marked on
luminaire label.
 Follow all manufacturer's warnings, recommendations
and restrictions for: driver type, burning position,
mounting locations/methods, replacement and
recycling.
CAUTION
RISK OF FIRE
 Keep combustible and other materials that can burn,
away from lamp/lens.
 Do not operate in close proximity to persons,
combustible materials or substances affected by heat
or drying.

Advertisement

loading
Need help?

Need help?

Do you have a question about the WBASC and is the answer not in the manual?

Questions and answers

Summary of Contents for Acuity Brands Lighting WBASC

  • Page 1 Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc. WARNING...
  • Page 2 Winona Lighting Synergy Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products. ABL LED General Warnings, Form No. 503.203 © 2010 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10...
  • Page 3 MA, see sheet 4 SPA & RPA, see sheet 2 WBA, see sheet 10 IS, see sheet 8 WBASC, see sheet 10 AASP/AARP/AAWB/AAWSC, see sheet 12 Lithonia Lighting Outdoor One Lithonia Way, Conyers, GA 30012 ©2016 Acuity Brands Lighting, Inc.
  • Page 4 (Fig 2c). Lithonia Lighting Outdoor One Lithonia Way, Conyers, GA 30012 Part Number: IM-459 Rev A ©2016 Acuity Brands Lighting, Inc. Phone: 800-279-8041 Fax: 770-918-1209 Revision Date: 8/29/19 www.lithonia.com All Rights Reserved.
  • Page 5 Secure wires; push back into pole and replace pole cap. Lithonia Lighting Outdoor One Lithonia Way, Conyers, GA 30012 Part Number: IM-459 Rev A ©2016 Acuity Brands Lighting, Inc. Phone: 800-279-8041 Fax: 770-918-1209 Revision Date: 8/29/19 All Rights Reserved. www.lithonia.com...
  • Page 6 Ensure no wires are at risk of being damaged by the drilling operation. Lithonia Lighting Outdoor One Lithonia Way, Conyers, GA 30012 Part Number: IM-459 Rev A Phone: 800-279-8041 Fax: 770-918-1209 ©2016 Acuity Brands Lighting, Inc. Revision Date: 8/29/19 All Rights Reserved. www.lithonia.com Page #4...
  • Page 7 Replace the rubber grommet back as originally assembled before wire feeding (See Figure 8b & 8c). Lithonia Lighting Outdoor One Lithonia Way, Conyers, GA 30012 Part Number: IM-459 Rev A Phone: 800-279-8041 Fax: 770-918-1209 ©2016 Acuity Brands Lighting, Inc. Revision Date: 8/29/19 www.lithonia.com All Rights Reserved. Page #5...
  • Page 8 25-30 in-lbs (overtightening can cause thread stripping and void all warranties). Lithonia Lighting Outdoor One Lithonia Way, Conyers, GA 30012 Part Number: IM-479 Rev A Phone: 800-279-8041 Fax: 770-918-1209 ©2016 Acuity Brands Lighting, Inc. Revision Date: 8/28/19 www.lithonia.com All Rights Reserved. Page #6...
  • Page 9 WARNING: USE AND PROPERLY TIGHTEN THRU-BOLT AND NUT. FAILURE TO CORRECTLY INSTALL COULD RESULT IN SERIOUS INJURY OR PROPERTY DAMAGE Lithonia Lighting Outdoor One Lithonia Way, Conyers, GA 30012 Part Number: IM-459 Rev A Phone: 800-279-8041 Fax: 770-918-1209 ©2016 Acuity Brands Lighting, Inc. Revision Date: 8/29/19 www.lithonia.com All Rights Reserved. Page #7...
  • Page 10 (2) 8-32 splice ac- cess cover fasteners. Lithonia Lighting Outdoor One Lithonia Way, Conyers, GA 30012 Part Number: IM-459 Rev A ©2016 Acuity Brands Lighting, Inc. Phone: 800-279-8041 Fax: 770-918-1209 Revision Date: 8/29/19 All Rights Reserved. www.lithonia.com...
  • Page 11 INSTALL COULD RESULT IN SERIOUS INJURY OR DEATH. Figure 14 Lithonia Lighting Outdoor One Lithonia Way, Conyers, GA 30012 Part Number: IM-459 Rev A Phone: 800-279-8041 Fax: 770-918-1209 ©2016 Acuity Brands Lighting, Inc. Revision Date: 8/29/19 All Rights Reserved. www.lithonia.com Page #9...
  • Page 12 ENSURE WEATHER–TIGHT INTEGRITY OF ELECTRICAL COMPONENTS (See Fig 13a or 13b) 1. Place the base plate in orientation shown in Figures 15a (WBASC) and 15b (WBA) and secure to wall with secure base plate to wall with (4) 1/4” diameter fasteners (not included with luminaire) using the (4) holes located on the outer corners of the base plate.
  • Page 13 9. Now, alternating between the top and bottom set screws, gently tighten until snug (approximately one thread will remain showing on each screw). Lithonia Lighting Outdoor One Lithonia Way, Conyers, GA 30012 Part Number: IM-459 Rev A Phone: 800-279-8041 Fax: 770-918-1209 ©2016 Acuity Brands Lighting, Inc. Revision Date: 8/29/19 All Rights Reserved. www.lithonia.com Page #11...
  • Page 14 8. Energize the luminaire to verify its operation and proper il- lumination of area. Lithonia Lighting Outdoor One Lithonia Way, Conyers, GA 30012 Part Number: IM-459 Rev A Phone: 800-279-8041 Fax: 770-918-1209 ©2016 Acuity Brands Lighting, Inc. Revision Date: 8/29/19 www.lithonia.com All Rights Reserved. Page #12...
  • Page 15 CAUTION: APPLY A CONTINUOUS BEAD OF WEATHER – PROOF CAULKING BETWEEN MOUNTING BASE PLATE AND WALL TO ENSURE WEATHER–TIGHT INTEGRITY OF ELECTRICAL COMPONENTS (See Fig 15a & 15b) 1. Install the wall-mount base plate, refer to steps 1-3 outlined in the WBA/WBASC installation instructions on sheet 9. Note that the image above shows the AAWSC option.
  • Page 16 8. Energize the luminaire to verify its operation and proper illumination of area. Lithonia Lighting Outdoor One Lithonia Way, Conyers, GA 30012 Part Number: IM-459 Rev A ©2016 Acuity Brands Lighting, Inc. Phone: 800-279-8041 Fax: 770-918-1209 Revision Date: 8/29/19 All Rights Reserved. www.lithonia.com...
  • Page 17 For Contractor Select configurations, refer table 1 on the next sheet for lumen output values. Lithonia Lighting Outdoor One Lithonia Way, Conyers, GA 30012 Part Number: IM-459 Rev A Phone: 800-279-8041 Fax: 770-918-1209 ©2016 Acuity Brands Lighting, Inc. Revision Date: 8/29/19 www.lithonia.com All Rights Reserved. Page #15...
  • Page 18 (overtightening can cause thread stripping and void all warranties). Lithonia Lighting Outdoor One Lithonia Way, Conyers, GA 30012 Part Number: IM-459 Rev A Phone: 800-279-8041 Fax: 770-918-1209 ©2016 Acuity Brands Lighting, Inc. Revision Date: 8/29/19 All Rights Reserved. www.lithonia.com Page #16...

This manual is also suitable for:

AaspAawbAarpAawscWbaSpa ... Show all