Advertisement

Quick Links

User Manual
10305001/10305002
Hephaestus 124/222
User Manual
Version 1.0
1

Advertisement

Table of Contents
loading

Summary of Contents for Holland Green Science 10305001

  • Page 1 User Manual 10305001/10305002 Hephaestus 124/222 User Manual Version 1.0...
  • Page 2: Table Of Contents

    User Manual Disclaimer & Warranty ....................3 LIMITED WARRANTY & DISCLAIMER ..................3 LIMITATION OF LIABILITY ....................... 6 Safety ..........................7 III. Hephaestus 124 and 222 Introduction ................. 9 After Sales Support .....................10 Proper Use .........................10 Technical Specifications ....................11 Standards and Conformity ...................12 Inspection ........................13 Packing List ........................13 VII.
  • Page 3: Disclaimer & Warranty

    User Manual Disclaimer & Warranty • The intellectual property rights for this manual belong to Holland Green Science Corporation (hereinafter referred to as “the Company”). • Products of the company are under the patent protection of China and other countries and regions (inclusive of obtained patents and patents currently under application).
  • Page 4 User Manual Company’s option, defective Products so as to cause the same to operate in substantial conformance with said published specifications; provided that Buyer shall (a) promptly notify the Company in writing upon the discovery of any defect, which notice shall include the product model and serial number (if applicable) and details of the warranty claim;...
  • Page 5 User Manual THE OBLIGATIONS CREATED BY THIS WARRANTY STATEMENT TO REPAIR OR REPLACE A DEFECTIVE PRODUCT SHALL BE THE SOLE REMEDY OF BUYER IN THE EVENT OF A DEFECTIVE PRODUCT. EXCEPT AS EXPRESSLY PROVIDED IN THIS WARRANTY STATEMENT, THE COMPANY DISCLAIMS ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, ORAL OR WRITTEN, WITH RESPECT TO THE PRODUCTS, INCLUDING WITHOUT LIMITATION ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE OR USE.
  • Page 6: Limitation Of Liability

    User Manual LIMITATION OF LIABILITY NOTWITHSTANDING ANYTHING TO THE CONTRARY CONTAINED HEREIN, THE LIABILITY OF THE COMPANY UNDER THESE TERMS AND CONDITIONS (WHETHER BY REASON OF BREACH OF CONTRACT, TORT, INDEMNIFICATION, OR OTHERWISE, BUT EXCLUDING LIABILITY OF THE COMPANY FOR BREACH OF WARRANTY (THE SOLE REMEDY FOR WHICH SHALL BE AS PROVIDED UNDER THIS SECTION) SHALL NOT EXCEED AN AMOUNT EQUAL TO THE LESSER OF (A) THE TOTAL PURCHASE PRICE THERETOFORE PAID BY BUYER TO THE COMPANY WITH RESPECT TO THE...
  • Page 7: Safety

    User Manual Safety IMPORTANT Safety Items to be Observed. Safety Warnings ! DANGER (may cause serious damage to property and / or casualties) 1. Please carefully read this User Manual prior to operating the instrument and observe the instructions on safe operation. 2.
  • Page 8 User Manual 17. Only accredited and qualified professional repair technicians can open the instrument or conduct required repairs. Persons performing repairs on the instrument other than those selected or approved by the Company shall operate to void any warranty contained hereinabove for the product 18.
  • Page 9: Hephaestus 124 And 222 Introduction

    User Manual III. Hephaestus 124 and 222 Introduction ③ ① ⑥ ② ④ ⑤ ① Control System ② Opening / Closing Handle ③ Shelf ④ ON / OFF Button ⑤ Power Outlet ⑥ USB Port ⚫ ④, ⑤ located at the back of the oven Version 1.0...
  • Page 10: After Sales Support

    User Manual After Sales Support If problems are encountered or technical support is required when installing or using the instrument, please contact serviceusa@hollandgreenscience.com The Company may provide technical assistance and information regarding the instrument or equipment or Service without charge at its sole discretion. Buyer assumes sole responsibility for any reliance on or use of such assistance and information, and the Company makes no warranty thereon.
  • Page 11: Technical Specifications

    User Manual Technical Specifications Model 10305001 10305002 Product Name Hephaestus 124 Hephaestus 222 124L 222L Chamber Volume Temperature Range Ambient+10℃~200℃ / Ambient+18℉~392℉) ±1℃/±1.8℉ Temperature Stability Display Resolution 0.1℃ / 0.1℉ Standard Quantity of Shelves Maximum of Shelves 20Kg Maximum Shelves Loading...
  • Page 12: Standards And Conformity

    User Manual Standards and Conformity Construction in Accordance with the following Safety Standards: UL 61010-1:2012 CSA C22.2#61010-1-12:2012 UL 61010-2-010:2019 CSA C22.2#61010-2-010:2019 Construction in Accordance with the following EMC Standards: EN 61010-1:2010 EN 61326-1:2013 Version 1.0...
  • Page 13: Inspection

    User Manual Inspection Packing List Unpack the equipment carefully and check for any damage which may have arisen during transport. In the event of identified damage, please contact serviceusa@hollandgreenscience.com. The package includes the following items Type Item Description Quantity Main Unit Drying oven Fittings Stainless steel wire shelves...
  • Page 14: Installation Requirements

    User Manual VII. Installation Requirements. 1. Set up only on bench-top or worktable that is dry, clean and stable with a flat horizontal surface. Ensure the required ventilation clearance space surrounding the instrument is 30-50 cm. (minimum). 3. The instrument should operate between 5°C (41°F) and 40°C (104 °F), and relative humidity maximum of 85%.
  • Page 15: Basic Mode (Prog 0) Or Program Mode (Prog 1

    User Manual Basic Mode (PROG 0) or Program Mode (PROG 1...8) Two operating modes are available: • Basic (PROG 0): program with a single working step • Programs (PROG 1...8): eight memorized programs, each consisting of 8 steps Depending on the program selected the display will show one of the following main screens: PROG 1...8 –...
  • Page 16: Programming

    User Manual Programming 8.5.1 Modification of Working Parameters - PROG 0 From the main screen of the PROG 0 mode, press the highlighted keys to change, from left to right, the temperature and the timer To increase or decrease the values of the temperature and or time, use the + and - keys.
  • Page 17: Modification Of Working Parameters - Prog 1

    User Manual 8.5.2 Modification of Working Parameters - PROG 1...8 From the main screen, press PROG to access the menu Select the required program to change by pressing the ‘yellow highlighted’ button and setting the corresponding digits using the numeric keypad. Confirm by pressing ‘ENTER’.
  • Page 18: Start/Stop Of A Program

    User Manual 8.5.3 Start/Stop of a Program To start or stop a program respectively press the START or STOP key. The keys are the same in both the main screens (PROG 0 or PROG1...8). The instrument then starts the set work cycle which can be one or more steps. NOTE: The timer countdown only starts when the set temperature is reached.
  • Page 19: User Setting Menu

    User Manual 8.5.3 User Setting Menu Press the ‘Gear’ icon and then ‘USER’ Version 1.0...
  • Page 20: Settings Date And Time

    User Manual 8.5.4 Settings Date and Time Press on any field of ‘Date and Time’ to access the menu Set the date and time using the numeric keypad as per the format; yyyy-mm-dd hh: mm: ss NOTE: It is necessary to set all the parameters (date and time) each time. 8.5.5 Frequency of Data Recording Click on the highlighted key to modify the frequency with which the instrument...
  • Page 21: Extended User Settings (Right Arrow)

    User Manual of 2000 records remains, however, the USB stick will act as secondary memory and it is possible to write records up to the USB stick capacity 8.6 Extended User Settings (Right Arrow) 8.7 Safety Temperature Limiter for Sample Protection The instrument has an alarm function to limit the maximum work temperature (Tm) so samples can be protected from an erroneous work temperature setting.
  • Page 22: Restart Mode After Absence Of Power Supply

    User Manual 8.8 Restart Mode After Absence of Power Supply It is recommended to use the ‘Restart’ mode of the instrument after a power supply absence (Po): Po VALUE DESCRIPTION On return of the power supply, the instrument does not automatically resume the heating cycle.
  • Page 23: Temperature Offset

    User Manual 8.10 Temperature Offset This function permits the setting of an offset value temperature measurement. NOTE: Whilst adjustable by an operator, a factory pre-set has been applied and should not be changed. Po VALUE DESCRIPTION Changing this parameter, you can correct the reading of PT100 sensor inside the instrument on one point temperature.
  • Page 24: Repetition Of Selected Program

    User Manual 8.12 Repetition of Selected Program This instrument function allows the repeat from 1 to 99 times of the selected program, function (Cycle). NOTE: It is possible to set a continuous repetition of a program, setting it in a continuous “loop”, with the parameter Cycle = 0.
  • Page 25: Fault Diagnosis

    User Manual Fault Diagnosis Fault Possible Causes Remedies Check power plug is fully Power plug not inserted. inserted into the socket. Check main power switch is ‘ON’ Power supply is not switched ‘On’ Check oven power is ‘ON’ No Power Upon Start-up Power switch broken Contact service Abnormal Temperature...
  • Page 26: Maintenance And Cleaning

    User Manual Maintenance and Cleaning Wipe down using only soap and water and a general use laboratory disinfectant. Rinse thoroughly with clean water and dry with a soft cloth. Caution: Avoid excessive use of water around the control area due to the risk of electrical shock. Damage to the controls may also result.

This manual is also suitable for:

10305002