5. Reconnect the cut portion (A) of the duct to
the blower housing. Ensure the fixing hole is
aligned with the tab in the base.
Fixing
Hole
Portion "A"
Left Side
Exhaust
6. Use the previously saved screw to secure the
duct in place through the tab on the the appli-
ance base.
7. For exhaust to the side of the cabinet, insert
the elbow and the duct.
Insert 4" Elbow
Through Rear Opening
Insert 4" Exhaust
Through Side Opening
8. Connect standard metal elbows and ducts to
complete the exhaust system.
Caution: Never leave the rear opening uncovered.
Install a cover plate.
9. Cover back opening with a plate (Kit
WE1M454) that is available from your local
service provider.
GEA00561
Plate
(Kit WE1M454)
10. Place the dryer in its final location.
GEA00562
GEA00563
– 7 –