• Never terminate the exhaust into a common duct
with a kitchen exhaust: a combination of lint and
grease could create a fire hazard.
• Do not obstruct incoming or exhausted air.
This dryer comes ready for rear exhausting. If
space is limited, use the "Dryer Exhaust to Left or
Bottom of Cabinet" instructions to exhaust directly
from the left side or bottom of the cabinet.
STANDARD REAR EXHAUST
Cut The Standard Exhaust
Duct To Proper Length.
Avoid Bunching Of The Duct
Behind The Dryer.
For Straight
Line Installation,
Connect The
Dryer Exhaust
To The Wall Using
Duct Tape
Elbow Highly
Recommended
Note: Elbows will prevent duct kinking and col-
lapsing.
Using Flexible Metal Ducts
If rigid all-metal duct cannot be used, then flexible
all-metal venting can be used, but it will reduce the
maximum recommended duct length. In special
installations when it is impossible to make connec-
tion with the above recommendations, UL-listed
clothes dryer transition duct may be used as
transition venting between the dryer and wall
connection only. The use of this ducting will affect
dry time.
If flexible transition duct is necessary, you must
adhere to the following directions:
• Use the shortest duct length possible.
• Stretch the duct to its maximum length.
• Do not crush or collapse the duct.
• Never use transition duct inside the wall or
inside the dryer.
• Avoid resting the duct on sharp objects.
• Venting must conform to local building codes.
GEA00554
Elbow Highly
Recommended
Recommended
Configuration
To Minimize
Exhaust
Blockage
GEA00555
– 5 –
GEA00556
Elbow Highly
Recommended
Do Not
Sit Dryer
On Flexible
Exhaust
Elbows Highly
Recommended
Do Not
Crush
Flexible
Exhaust
Against
Wall.
Elbow Highly
Recommended
GEA00557