14.7 SETTING THE WATER REGULATION VALVE

The water regulation valve is preset to factory default values. These may
change due to possible shocks and vibrations during transportation.
In this case, the water regulation valve has to be reset properly by authorized
servicing personnel.
The water regulation valve functions properly when tepid water is discharged
from appliance during the operation of the compressor unit; the water flow stops
when the appliance stops. Water consumption increases if the temperature of
cooling water exceeds 18° C.
14.8 DANGER OF TEMPERATURES BELOW 0 ° C
Do not leave the appliance in an environment colder than 0ºC (273K). If this is
the case, discharge water from the condenser.
In order to empty the water out of the appliance, unscrew the cap of the safety
valve (in counter clockwise direction).
After that, open the valve (in counter clockwise direction) in order to release
water out of the system.