3.4 PLACING THE APPLIANCE ON THE GROUND

Place the machine on a level solid non-combustible surface with an adequate
strength of at least 600 kg per m² for the weight of the machine, and position the
appliance at least 60 cm away from the wall or other objects. Leave enough
space in front of the appliance to ensure comfortable access and work with the
appliance.
While placing the appliance in position, block the front wheels (by pressing the
brake), which will ensure that the appliance will not be able to move.
4 REQUIREMENTS
NORMAL OPERATION OF THE APPLIANCE
Before connecting the appliance to electricity supply, the operator must make
sure that environment requirements have been met: the temperature and
humidity of the air must be appropriate and the water supply and electricity
networks comply with all requirements for normal operation of the appliance.
When the characteristics of either the water supply or electricity network fail to
meet the requirements for normal operation, the machine must not be
connected to power supply.

4.1 ENVIRONMENTAL CONDITIONS

Prior to connecting the appliance, the temperature and the humidity of the
environment, in which the appliance will be operated, must be assessed and
checked.
AIR TEMPERATURE
AIR HUMIDITY
If room temperature drops under 0 ºC (273K), water must be released from the
condenser.
AND
CONDITIONS
min.
max.
10° C
38° C
0%
85%