Start-Up & Operating Procedures - Pelsue 1450 Product Manual

Centrifugal blower
Table of Contents

Advertisement

Prior to Operation, the #1�50 Centrifugal Blower should be configured and prepared according to the following guide-
lines.
1. Pre-Operation Inspection:
It is necessary to perform a visual inspection, each time, prior to using the product. If deficiencies are found, remove the
product from service and contact the T.A. Pelsue Company regarding repair. The following checklist coupled with Figure
#5.2a should be used as a guide to determine whether the equipment is in good operating condition prior to usage.
Equipment that is not in good condition can endanger the safety of the entrant(s) and attendant(s) during use.
The Pre-Operation Visual Inspection is not limited to, but must include the following items;
a. Check the blower inlet and outlet grilles for obstructions.
b. Ensure that the exhaust and the air intake of the engine are not obstructed.
c. Check the fuel and oil levels in accordance with the engine manual.
d. Remove any objects around the immediate area that could be drawn into the blower.
e. Ensure that the rubber feet and vibration springs are attached.
f. Ensure that the spark plug wire is connected to the spark plug.
g. Ensure that the cap on the fuel tank is securely tightened.
OUTLET
GRILLE
INLET
GRILLE
#104749-001 - Product Manual: Model #1450 CENTRIFUGAL BLOWER - Revision 06 - Date: 06-05-2015
5.2 - Start-Up & Operating Procedures
Figure #5.2a: #1450 Centrifugal Blower
Pre-Operation Inspection Points
ENGINE
ExHAUST
GAS
CAP
ENGINE
AIR FILTER
RUBBER FEET
& VIBRATION SPRING
Page 13