Parameter description
6.F Running History Record
Code
Description
6.P Protection Parameters
Code
Description
FP.00
User password
Parameter
FP.01
write-in
protection
Parameter
FP.02
initialization
Parameter
FP.03
copy
Parameter
FP.04
upload
protection
G/P model
FP.05
selection
User
FP.07
parameters
backup
SINAMICS V50 converter
67
Operating Instructions, 04/2022, FW V1.0, A5E44777205B AB
Setting range
Setting range
0~9999
0: No password
Others: password
protection
0: All parameters
are allowed
modifying
1: Only FP.01 and
FP.03 can be
modified
2: All parameters
are not allowed
read
0: No operation
1: Clear fault
history
2: Restore to
defaults
0: No action
1: Parameters
download
2: Parameters
upload (except
motor's
parameters)
3: Parameters
upload (all
parameters)
0: Protection enabled
1: Protection disabled
0: Type G
1: Type P
0: Invalid
1: Valid
Default
Modify
Default
Modify
0
о
0
о
0
X
0
X
0
X
0
X
0
X
Modbus
Address
Modbus
Address
-
-
-
-
-
-
-