Parameter description
6.5 Motor Parameters
Code
Description
Mutual
F5.09
Inductive
reactance Xm
F5.10 Auto tune
Synchronous
F5.11
motor
stator
resistor Rs
Synchronous
F5.12
motor
D-axis
inductance Ld
Synchronous
motor
Q-axis
F5.13
inductance Lq
Synchronous
F5.14
motor counter
EMF constant
SINAMICS V50 converter
42
Operating Instructions, 04/2022, FW V1.0, A5E44777205B AB
Setting range
0.01~655.35 mH
0: No operation
1: Static tuning
2: Rotary tuning
0.1 ~6553.5 mOhm
0.001~65.535 mH
0.001 ~65.535 mH
0.0~6553.5 V
Default
Modify
Depends on
о
model
0
X
Depends on
о
model
Depends on
о
model
Depends on
о
model
300.0 V
о
Modbus
Address
0609H
060AH
060BH
060CH
060DH
060EH