PROCAM DISTRIBUTION Villa Pergola User Instructions

Assembly and motorized operation

Advertisement

Quick Links

User Instructions
Villa Pergola for motorized operation
SIZE: 300X300 / 300X400 CM
1-844-776-2266
WWW.PROCAMDISTRIBUTION.CA
INFO@PROCAMDISTRIBUTION.CA

Advertisement

Table of Contents
loading

Summary of Contents for PROCAM DISTRIBUTION Villa Pergola

  • Page 1 User Instructions Villa Pergola for motorized operation SIZE: 300X300 / 300X400 CM 1-844-776-2266 WWW.PROCAMDISTRIBUTION.CA INFO@PROCAMDISTRIBUTION.CA...
  • Page 2: Table Of Contents

    CONTENT TOOLS AND MAN FORCE ........3 PARTS LIST ............4 PRODUCT DESCRIPTION........6 IMPORTANT SAFETY INSTRUCTIONS ....7 MOUNTING AND USAGE ........8-17 MOTOR SETUP............18 DISMOUNTING ...........19 STORAGE ............19 DISPOSAL ............19...
  • Page 3: Tools And Man Force

    MOUNTING AND USAGE. KEEP THIS MANUAL FOR FUTURE REFERENCE. Dear Customer, We, Procam distribution thank you for buying our Villa Pergola. To enjoy this product for a long time and for your own and other people's safety, please follow the assembly's instructions.
  • Page 4: Parts List

    ATTENTION: PLEASE CHECK ALL PARTS AGAINST THE PARTS LISTED BEFORE STARTING THE PERGOLA'S CONSTRUCTION. PARTS LIST HARDWARE AND OTHER PARTS: ① M8*20 countersunk screw ② 50 to 40 connector ③ Base plate ④ Upright cover ⑤ M10 screw cap ⑥ M8*20 Hexagon bolt ⑦...
  • Page 5 ALUMINUM PROFILE PARTS LIST: Ⓐ Beam Ⓖ Common louver Ⓑ Beam with motor Ⓗ Center louver Ⓒ Beam Ⓘ Driving louver Ⓓ Post + Post Connector Ⓙ Control rod ⒺⒻ Gutter...
  • Page 6: Product Description

    300 x 300 : 2960 x 2960 mm 300 x 400 : 2960 x 4031 mm PRODUCT DESCRIPTION Make the most of your outdoor living area with your pergola. Relax and enjoy the outdoors while being protected from sun. The coated aluminum frame pergola is perfect for shading your garden, deck, courtyard and swimming pool.
  • Page 7: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS WARNING: FOR YOUR AND OTHER PEOPLE’S SAFETY, IT IS IMPORTANT TO FOLLOW THE INSTRUCTIONS BELLOW AND OBEY WARNINGS. SYMBOL EXPLANATION This warning triangle calls attention to hazards that can lead to death or to severe injuries or to the primordial elements for the functioning of the Pergola.
  • Page 8: Mounting And Usage

    MOUNTING AND USAGE STEP 1 Attach base plate ③ x4 to the bottom of posts (D1 x1, D2 x2 and D3 x1), use bolts ① x8 to attach with hex key or electric drill D2 posts should be installed diagonally as below...
  • Page 9 MOUNTING AND USAGE STEP 2 Attach beams Ⓐ x1, Ⓑ x1, and Ⓒ x1, use bolts ⑥ x12 to fasten...
  • Page 10 MOUNTING AND USAGE STEP 3 Attach beam Ⓒx1, use bolts ⑥ x12 to fasten...
  • Page 11 MOUNTING AND USAGE STEP 4 Attach upright cover ④ x4, use bolts ⑥ x8 to fasten...
  • Page 12 MOUNTING AND USAGE STEP 5 Attach all four gutters (Ⓔ x2 and Ⓕ x2) by hooking inside the Ⓐ, Ⓑ and Ⓒ beams...
  • Page 13 MOUNTING AND USAGE STEP 6 Located holes in center of beams (Ⓐ and Ⓑ) 3x3: Place centre louver Ⓗ into 12th slot, lining up with the holes for 300x300cm size. 4x3: Place centre louver Ⓗ into 16th slot, lining up with the holes for 400x300cm size. Using M10 nut ⑤...
  • Page 14 MOUNTING AND USAGE STEP 7 Fasten motor ⑨ x1 as shown below.
  • Page 15 MOUNTING AND USAGE STEP 8 Fasten ⑪ x4 gutter connector and ② x1 (50 to 40 connector). Connect the female and male plugs for the LED lighting (DC24V to DC24V) and motor (DC24V to DC24V) and plug the power cable into local socket. Main Power DC24V DC24V...
  • Page 16 MOUNTING AND USAGE STEP 9 Fix Ⓙ x4 (flat L-shaped aluminum profile). One for each other of the slats is required. 3x3: Use bolt ⑥ x46, plastic spacer ⑦ x46 and nut ⑧ x46 to tighten 4x3: Use bolt ⑥ x64, plastic spacer ⑦ x64 and nut ⑧ x64 to tighten Secure the louvers at each end.
  • Page 17 MOUNTING AND USAGE STEP 10 Mark holes for expansion bolt ⑩ x4 on each post. NOTE: the drill size should be 12 mm. Insert the bolts. Use a hammer drill if necessary. Place the posts over the bolts. Tighten the nuts. Once installed, make sure any remaining plastic is removed and silicone is used along all corners and gutters to waterproof.
  • Page 18: Motor Setup

    MOTOR SETUP 86 OPERATION INSTRUCTIONS FOR DC CONTROLLER WITH LAMP CONTROL CHARACTERISTICS • Exquisite and unique appearance design; • 86*86 national installation standards; • Using impulse current relay; • Adopting precision SMT process, surface moisture-proof treatment; • Parts of electrical apparatus meet the requirements of fire safety standards for electrical standards;...
  • Page 19: Dismounting

    ATTENTION: ENSURE LOUVERS ARE OPEN DURING PERIODS OF MILD TO STRONG WINDS. DISMOUNTING IF YOU WANT TO DISASSEMBLE THE PERGOLA, PLEASE FOLLOW THE FOLLOWING PROCESS. ATTENTION! SAFETY HINTS AND INSTRUCTIONS MUST BE FOLLOWED FOR DISMOUNTING AS WELL. AT LEAST TWO PEOPLE ARE NEEDED FOR THIS STEP. Keep the Pergola louvers open before you begin with dismounting.
  • Page 20 1-844-776-2266 WWW.PROCAMDISTRIBUTION.CA INFO@PROCAMDISTRIBUTION.CA...

This manual is also suitable for:

Zc31-03-2ad

Table of Contents