REPAIR
The following maintenance requires professional or qualified maintenance
personnel to perform maintenance
1. Electronic control maintenance
a. Remove the 8 fixing screws of the electric control cover of the
machine, and use a wrench to unscrew the faucet fixing ring.
b. Open the electric control cover to repair the electrical part.
ELECTRIC
CONTROL BOX

DEHUMIDIFIER STORAGE

When you do not use this product for a long time and
plan to store or collect it, pay attention to the following steps:
1. In the power-on state, press the drain button, wait for a while, and
press it again until the water is drained.
2. Roll up the power cord and water hose and secure them in place.
3. Clean the filter.
4. Place in a cool, dry, relatively dust-free environment. Do not place in
chemical environment.

TROUBLESHOOTING

If the following conditions occur, please confirm the following conditions
before requesting customer service:
DESCRIPTION
POTENTIAL CAUSE
Is the power cord properly
connected?
Machine
Is the room temperature above 5°C
Not Running
or within 38°C?
Is the filter blocked?
Does Not
Are the air inlets or
Dehumidify
air outlets blocked?
No Wind Enters
Is the filter blocked?
Is the machine placed at an angle?
Loud Noise
When Running
Is the filter blocked?
Does Not
Mechanical sensor failure or
Turn On After
disconnected wiring
Humidity Setting
Defrost Time
The temperature switch is faulty
Too Long
and the temperature is low
Water Leakage
Discounted or clogged water pipes
SOLUTION
Connect the plug and socket
Machine must operate at normal
operating temperature
Clean the filter
Clear the blockage from the
air inlet or outlet
Clean the filter
Move the machine to a flat,
sturdy location
Clean the filter
Replace accessories or check
wiring and connect
First judge whether it is caused
by the ambient temperature for
too long or better to sense the
temperature switch
Check the connection and status
of water pipes