AOVX G Series Quick Start Manual

AOVX G Series Quick Start Manual

Assets tracker

Advertisement

Quick Links

WE TRACK AND
PROTECT YOUR
ASSETS
Assets Tracker Quick Start Guide
V1.1
www.aovx.com
G Series

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the G Series and is the answer not in the manual?

Questions and answers

Summary of Contents for AOVX G Series

  • Page 1 WE TRACK AND PROTECT YOUR ASSETS Assets Tracker Quick Start Guide G Series V1.1 www.aovx.com...
  • Page 2: Table Of Contents

    G Series Quick Start Guide Contents 1 Product Application ............................1  1.1 Instructions  ............................ 1   1.2 Product Function .......................... 1   1.3 Light Density Monitoring  ........................ 2   1.4 Motion Detection .......................... 3   1.5 Local Storage Loss Alarm ........................ 3   1.6 Low Power Alarm .......................... 3   1.7 Electronic Fence .......................... 3   1.8 OTA Upgrade ............................. 3   2 Parameter Configuration ..........................4  3 Platform Management ........................... 7 ...
  • Page 3: Product Application

    1.2 Product Function G series device can be configured locally via USB port and remotely through command from server. The parameters include sampling and report interval, alarm threshold. Below is the main functions and data report logic of G series device.
  • Page 4: Light Density Monitoring

    G Series Quick Start Guide 3.2.1. Location Reporting Function Periodic reporting: The default configuration is to obtain location information every 10 minutes and store it locally, then report to the platform every hour. When the GNSS positioning fails, the base station or WiFi positioning will be activated as assistance. If the device does not detect the network, it will stop reporting, and enters sleep mode.
  • Page 5: Motion Detection

    G Series Quick Start Guide Triggered reporting: when the light density exceeds the threshold, it will trigger an alarm to the platform. 1.4 Motion Detection Periodic reporting: the default configuration is to obtain assets movement every 10 minutes and store it locally. Then report the motion status to the platform every hour. At the same time, it will record and judge the movement status, and generate a report if it’s static for too long.
  • Page 6: Parameter Configuration

    G Series Quick Start Guide 2 Parameter Configuration Open the configuration tool and connect the device. If you need to configure the APN, please confirm the APN with the card issuing operator. Follow the steps below to set it up: (1) Please connect the device to the computer via a USB cable.
  • Page 7 G Series Quick Start Guide (3) Open COM Port. (4) Query current parameter and version, data is shown is display area and filled in parameter area. (5) Find the parameter you want to change input value or choose status, then click on the box on the right.
  • Page 8 G Series Quick Start Guide...
  • Page 9: Platform Management

    Customers can use our platform, as well as third-party or your own platforms. The configuration and user guide are as follows. 3.1 AOVX Cloud Platform Website: http://login.yunxion.com/, user name and password are provided by AOVX administrator. 3.1.1. Add Goods Enter Goods Management—Goods List, Add Goods. Fill in requested information, so it’ll be easy to search your assets or goods.
  • Page 10 G Series Quick Start Guide 3.1.2. Add Device Enter Device Center—Device List, Add Device. The IMEI must be consistent with the label on the back of the device. Only by adding goods and device at the same time, they can be bound correctly, then the route will be correctly displayed.
  • Page 11 G Series Quick Start Guide 3.1.4. View History Route...
  • Page 12 G Series Quick Start Guide 3.1.5. View Current Position 3.1.6. Check Temperature and Humidity Information...
  • Page 13: Third-Party Or Customer-Owned Platform

    G Series Quick Start Guide 3.2 Third-Party or Customer-Owned Platform Please refer to the device interface protocol AOVX_Assets Tracker_G_Series_Cloud Platform Protocol .
  • Page 14: Faq

    G Series Quick Start Guide 4 FAQ 4.1 Vibration Alarm Test Hold the device and shake it back and forth quickly. When the motion count exceeds the preset value, an alarm will be triggered. You can check the platform to view the alarm.
  • Page 15: Temperature And Humidity Alarm

    G Series Quick Start Guide 4.2 Temperature and Humidity Alarm The humidity threshold can be set lower than the normal environment as required by the test. As long as the ambient temperature and humidity exceeds the set threshold, the high temperature and humidity alarm will be triggered.
  • Page 16: Position Unfixed Or Huge Deviation

    G Series Quick Start Guide 4.4 Position Unfixed or Huge Deviation Question1: It’s impossible to receive good signals where satellites are blocked, such as underground or under high buildings Solution1: Move to open area with good satellite signal Question2: Device is faced down or blocked by metal Solution2: Put the device correctly or change to another position.
  • Page 17 WE TRACK AND PROTECT YOUR ASSETS AOVX Assets Tracker Solutions Corp. Website:www.aovx.com Mail:info@aovx.com Tel:+86 18949864976...