AOVX VX300 Quick Start Manual

AOVX VX300 Quick Start Manual

Vehicles tracker

Advertisement

Quick Links

AOVX VX300 Quick Start
Vehicles Tracker
V2.2
1
www.aovx.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VX300 and is the answer not in the manual?

Questions and answers

Summary of Contents for AOVX VX300

  • Page 1 AOVX VX300 Quick Start Vehicles Tracker V2.2 www.aovx.com...
  • Page 2: Table Of Contents

    V2.1 2022/03/28 YUKI Upgrade layout 2.3 How to install USB driver ..............6 2.4 Local configuration ................7 V2.2 2022/04/01 YUKI Upgrade information of USB cable and config 3 LED light indications ................9 tool Safety Information ..................10 www.aovx.com...
  • Page 3: Introduction

    1 Introduction 1.1 Device overview Figure_1 Overview of VX300 NOTE: Please use the USB cable provided by AOVX. www.aovx.com...
  • Page 4: Wiring Sequence

    1.2 Wiring sequence Table2 VM300/VL300 Table1 VG300 COLOR SIGNAL COLOR SIGNAL Black Black Orange Orange Yellow Relay Yellow Relay Brown DI1/AI1 White Figure_2 four wires Figure_3 six wires www.aovx.com...
  • Page 5: Set Up Your Device

    3 Connect the device to the car fuse box according to the wiring sequence,or click How to install VX300. If it is tested in the laboratory or office, ACC shall be powered , could connect circuit ACC and VCC before connecting to DC power supply NOTE: Please note that device will automatically enter sleep after one minute if ACC is not powered .
  • Page 6: How To Connect To Computer

    3 After installation,go to Device Manager and check for the “Prolific USB-to-Serial Com Port” device and the COM port number assigned by Windows. 4 You are now ready to use the device on your computer. Figure_5 Connect device via cable Figure_6 Check COM port www.aovx.com...
  • Page 7: Local Configuration

    2 Make sure you click set after every configuration.Most important configurator section is Quick Start – where all your server and network can be configured.More details about V series configuration can be Figure_7 Config tool window found in VX300 User Manual. www.aovx.com...
  • Page 8 Crash level:Report when crash level over 460 by default. GPIOMODE=<channel>,<mode> configure GPIO MODE Timezone:UTC+8 by default. More details about SMS commands can be found in AOVX AT commands. Run Voltage:It’s in run mode while over 13500V by default.(only for VG300) Default configuration settings Sleep Voltage:It’s in sleep mode while lower 11850V by...
  • Page 9: Led Light Indications

    No power or in sleep mode No power or in sleep mode Network LED indication Table 5 Network LED flash Searching GNSS COLOR STATE MEANING Linking server succeeded green No power or in sleep mode flash Searching for network or linking servers www.aovx.com...
  • Page 10: Safety Information

    VX300 location on your vehicle. In case you are not sure about proper connection, please consult qualified personnel. This message contains information on how to operate VX300 safely. By following these requirements and recommendations, you will avoid The programming must be performed using a PC with dangerous situations.