Download Print this page

Advertisement

Quick Links

ACCESS200 installation guide
1. Install readers
Fix the base part to a single gang box or directly to the mounting surface.
Use 3 mm diameter countersunk head screws. Heads must not stand out
more than 1 mm from the base surface.
When using stranded wires, make sure there are no wires outside the
cages of the pluggable cage clamp.
To avoid rain interference, mount outdoor keypad readers upright or
at a protected spot. Otherwise, ensure large water drops are wiped off
if readers are malfunctioning.
Pigtail cable connection / Molex Pico-SPOX (outdoor/potted
versions) stranded, AWG28, power Red&Black AWG 24
Color
Connector pin #
White/Orange
Orange
White/Green
Green
Red/White
Black/White
Red
Black
White/Blue
Blue
White/Brown
Brown
2. Optional: Set bus address
When using a bus protocol (e.g. OSDP), set a bus address for each reader: Place a BALTECH AdrCard
in front of the reader and wait for the signal indicating the desired address.
If readers are already configured, the reader housing (i.e. the tamper switch) must be open.
Learn more:
docs.baltech.de/bus-address
BALTECH AG
Phone:
Lilienthalstrasse 27
Fax:
85399 Hallbergmoos
Mail:
Germany
Website:
Signal/funct.
1
WIE_D0/RS485A
2
WIE_D1/RS485B
3
4
5
USB Data -
6
USB Data +
7
8
9
10
11
12
+49 (811) 99 88 1-0
+49 (811) 99 88 1-11
info@baltech.de
www.baltech.de
J8 Pluggable cage clamp
(indoor versions)
Pin #
J8-1
J8-2
LEDGN
J8-3
LEDRD
J8-4
J8-5
J8-6
+VIN
J8-7
GND
J8-8
GND
J8-9
REL_WC
REL_NO
REL_NC
Connector and pins
(reader rear view)
Signal/funct.
GND
+Vin
WIE_D0/RS485A
WIE_D1/RS485B
LEDGN
LEDRD
REL_WC
REL_NO
REL_NC
v1.1
p 1/2

Advertisement

loading

Summary of Contents for Baltech ACCESS200

  • Page 1 REL_NC 2. Optional: Set bus address When using a bus protocol (e.g. OSDP), set a bus address for each reader: Place a BALTECH AdrCard in front of the reader and wait for the signal indicating the desired address. If readers are already configured, the reader housing (i.e. the tamper switch) must be open.
  • Page 2 3. Optional: Deploy Prox license To deploy a Prox license for HID Prox, Indala, or Keri card support, present a BALTECH LicenseCard to each reader. Successful deployment is signaled by a yellow and green LED sequence. Learn more: docs.baltech.de/licensecard 4. Optional: Test reader functionality By default, the readers will now read any card’s UID (serial number) and transmit it to the host...