opened with the handle on the bottom or the two finger tabs on the side of the unit. Slide the drawer completely out of
the unit. Slide the cover back to access the filter. Remove the existing filter and replace with a new filter. The filter
dimensions are a nominal 12" x 12" x 1" and may be purchased from Nature's Cooling Solutions. The filter has a
direction indicator for the airflow direction. The filter should be installed so the airflow goes toward the top of the filter
drawer. Replace the filter drawer for operation.
Set up and customization
EcoBreeze 2.2 can be customized for different conditions or user preferences.
The standard settings for EcoBreeze 2.2 are:
Auto low Fan Speed – 6
Display Light setting - High
Filter change – 500 hours
Temperature scale – Fahrenheit
The settings can be changed by pressing the setup button. It will revert back to the run operation when it does not
sense any additional input for 10 seconds.
First press of button – Displays thousands and hundreds of hours of fan run time
Second press of set button - Displays tens and single digit of hours of fan run time. The unit only has 2 positions on the
display so combining the first and second display would give lifetime run hours. I.e. 01, 95 would be 0195 hours of fan
run time. This will provide information on actual hours of natural cooling that the fan is providing. (Like a car odometer)
Third press of the set button – Displays the outdoor temperature
Fourth press of the set button – Displays the indoor humidity dew point temperature
Fifth press of the set button – Displays the outdoor humidity dew point temperature
Sixth press of the set button – This will customize the Maximum fan speed for the low auto mode (1). The lower fan
setting will limit the fan speed in the quiet mode. The settings are 1-10. Press + or – to raise or lower the maximum
speed based on your preference.
Seventh press – Customize display light level for your preferences.
0 – Off - in this mode the display will be off unless a button is pressed. When any button is pushed the display
will illuminate for 30 seconds and they return to the off mode.
1 – Dim
2 – Medium
3 – Maximum
Eighth press of set button – displays the hours remaining until the filter needs to be changed. Press +/- to reset to the
maximum hours
Ninth press of the set button – Filter change. Customize the hour of run time between filter changes. The hours are
the display times 10. A display of 50 represents a setting of hours. This is preset at 500 hours. For an area with a high
level of outdoor pollution decrease the hours between changes. For areas with a low level of outdoor pollution increase
the hours. Press + or – to raise or lower the hours.
Tenth press of the set button – Select temperature scale. Press + or – to toggle between Fahrenheit and Centigrade.
Push set
Display
st
1
Hours of run time - thousands & hundreds
nd
2
Hours of run time – tens and single digits
rd
3
Outdoor Temperature
th
4
Indoor dew point
th
5
Outdoor dew point
Push set
th
6
Auto low Maximum fan speed - 1 low, 10 high
th
7
Light level
th
8
Filter Hours Remaining +/- reset to max
th
9
Max Filter hours (x10) 10 to 100
th
10
Temperature scale
877-565-1457
Display
Change +/-
0 off, 1 dim, 3 bright
F or C