Download Print this page
OrienTek TFI-40 User Manual

OrienTek TFI-40 User Manual

Fiber identifier

Advertisement

Quick Links

T F I - 4 0 F i b e r I d e n t i fi e r U s e r M a n u a l
Products introduction
The fiber identification instrument is an essential tool for
fiber maintenance. It is used for non-destructive fiber
identification. It can be detected at any position of
single-mode and multi-mode fiber. During maintenance,
installation, wiring and recovery, it is often necessary to
continue without interruption. In the case of business, find
and separate a specific optical fiber, by injecting a
1310nm or 1550nm band modulation (270Hz, 1KHz, 2KHz)
signal into the optical fiber at one end, and use the
recognizer to identify it on the line, and it can also indi-
cate the signal direction. This product integrates VFL red
light function and LED lighting function. The VFL uses a
2.5mm universal interface with an output power of up to
1mW, which can detect fiber breaks or corners within
5KM. The VFL red light source supports pulse and contin-
uous wave operation. Equipped with LED lighting function,
convenient for construction in the dark.
1
3
4
5
6
7
1
Fixture cover
2
Plunger detachable, use on the
front and back, choose the cor-
responding surface according to
the thickness of the fiber
3
Optical components
4
Fiber groove
5
battery cover
2
4
2mm/3mm
front
250/900μm
9
back
5
6
8
Fixing screws
6
2*1.5V alkaline battery
7
8
Dust cover: built-in VFL interface
(2.5mm universal interface) and
LED lighting
9
Lock button
Panel features open
1
2
3
5
1
LCD display-display power value, frequency.
2
Direction indicator-indicating the direction
of the optical fiber light source under test.
3
Power-power on/off.
4
Backlight-Switch the backlight function [On] or [Off].
5
VFL key-- turn on/off the VFL function.
Fiber signal recognition
1.Put the fiber to be tested into the groove of the
fixture, push the button to lock the fixture, and
install the fixture cover .
5. 9
270
2.If there is a signal in the optical fiber, the left and
right direction lights show the signal direction.
3.If there is no signal in the optical fiber, the LCD
display shows LO, and the direction indicator light
may flicker left and right. When the fiber is not
clamped, the direction light may also flicker left and
right
4.When the signal frequency is 2KHz, 1KHz, 270Hz,
the corresponding indicator light is on, accompanied
by a buzzing sound (when the signal is too weak, it
will not be correctly identified).
Note: This product does not specify power accuracy
and should not be used to determine the actual signal
strength in the fiber.
5. 9
dB
270
Hz
2
4
dB
Hz

Advertisement

loading

Summary of Contents for OrienTek TFI-40

  • Page 1 T F I - 4 0 F i b e r I d e n t i fi e r U s e r M a n u a l Products introduction Panel features open The fiber identification instrument is an essential tool for fiber maintenance.
  • Page 2 Recognize 270Hz, 1Hz, 2KHz modulation signal. Online testing, no need to interrupt the business, one- touch operation mode, simple and convenient. NANJING ORIENTEK OPTICAL COMMUNICATION LTD Be equipped with LED light,more convenient to work TEL: +86 17312230635 in the dark.