(1) Input signal level
All the input signals are at the TTL level.
High level --- 2.0 V at minimum
Low level --- 0.8 V at maximum
(2) Output signal level
All the output signals are at the TTL level.
High level --- 2.4 V at minimum
Low level --- 0.4 V at maximum
(3) Input and output conditions
The STROBE and RESET input signals are pulled up at 10k , and the other input signals at 50k ,
respectively.
[Printer Side]
All the output signals are pulled up at 50k .
[Printer Side]