Fisher & Paykel MINIMAL CID834DTB4 Installation Manual page 10

Downdraft induction cooktop
Hide thumbs Also See for MINIMAL CID834DTB4:
Table of Contents

Advertisement

ISO: VENTING TO REAR
Rear edge
of cutout
72 33
105
PROFILE: SEPARATE HOUSING
All dimensions are in mm
10
VENTING PREPARATION
Rear edge
of cutout
65 35
100
PROFILE: SHELVING
VENTING TO THE REAR
Through same cabinetry
This can be acheived using the supplied components. When ducting is centred below
z
cooktop, a maximum venting height of 1067mm* is possible, alongside a maximum venting
depth of 93mm***. These distances can be extended by using accessory kit D1-C-222-89.
When ducting is directly below the outlet, a maximum venting height of 847mm* is possible,
alongside a maximum venting depth of 93mm***.
A space of 105mm is required at the rear of the cabinetry to house the vertical ducting
z
components**. Alternately, if vertical ducting is to pass through any shelving, ensure a
cutout of 232mm x 100mm has been created in all shelves.
Every 3m or additional bend drops extraction performance by 2%.
z
Through adjacent cabinetry
This can be achieved through the use of a minimum of 2x E90-H-222-89 and 1x D1-C-222-89
z
accessory kits.
A space of 105mm is required at the rear of the cabinetry to house the vertical ducting
z
components**. Alternately, if vertical ducting is to pass through any shelving, ensure a
cutout of 232mm x 100mm has been created in all shelves.
Every 3m or additional bend drops extraction performance by 2%.
z
Through sub-floor
This can be acheived using the supplied components with a maximum venting height of
z
712mm* possible.
A space of 105mm is required at the rear of the cabinetry to house the vertical ducting
z
components**. Alternately, if vertical ducting is to pass through any shelving, ensure a
cutout of 232mm x 100mm has been created in all shelves.
Every 3m or additional bend drops extraction performance by 2%.
z
Direct from outlet
This can be achieved through the use of a D1-C-222-89 accessory kit.
z
When venting directly back from the outlet, the top of the ducting will sit 80mm below the
z
cooktop glass.
Every 3m or additional bend drops extraction performance by 2%.
z
VENTING TO THE SIDE
This can be achieved through the use of a minimum of 2x E90-H-222-89 and 1x D1-C-222-89
z
accessory kits and can be configured via the front or the rear.
A space of 105mm is required at the rear of the cabinetry to house the vertical ducting
z
components**. Alternately, if vertical ducting is to pass through any shelving, ensure a
cutout of 232mm x 100mm has been created in all shelves.
Access through the base of the cabinetry to connect ducting components is recommended.
z
Every 3m or additional bend drops extraction performance by 2%.
z
*From underside of glass to base of outlet
**When vertical ducting is housed within cabinetry only
***From rear edge of glass to end of duct

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cid834dtb4

Table of Contents