DESCRIPTION OF THE CONNECTORS / INTERFACES ..........6 MECHANICAL DIMENSION ....................9 POWER SUPPLY REQUIREMENT ................... 10 ORDERING INFORMATION ....................10 DECLARATION OF CONFORMITY CE-MARKING ............11 ERROR CODES ........................12 CONTACT ADDRESSES ....................12 NTI AG Installation: E1000/E2000/E4000 series / 16.09.2005 Page 1/12...
The information in this documentation reflects the stage of development at the time of press and is therefore without obligation. NTI AG. reserves itself the right to make changes at any time and without notice to reflect further technical advance or product improvement.
Linear Motor with internal Position Feedback Complete E4000 Controller based system (E1000 and E2000 controllers will only drive one respectively two motors). Power Supply for Signal and Motor may be the same device (see later). NTI AG Installation: E1000/E2000/E4000 series / 16.09.2005 Page 3/12...
RUN - INIT + 5 ... 24 V use only INIT - shielded cables Picture shows typical wiring of a single axes controller. Multiple axes controller will have additional motor connectors. NTI AG Installation: E1000/E2000/E4000 series / 16.09.2005 Page 4/12...
Do not switch Power Supply DC Voltage. All power supply switching and E-Stop breaks should be done to the AC supply voltage of the power supply. Failure to observe these precautions may result in severe damage to controller. NTI AG Installation: E1000/E2000/E4000 series / 16.09.2005 Page 5/12...
(In the state ERROR a blink code of the STAT LEDs A and B tells what the actual error is. The blink codes are explained in chapter ‘Service’of the user Manual.) NTI AG Installation: E1000/E2000/E4000 series / 16.09.2005 Page 6/12...
Page 7
DSUB-9 (male) ID high ID low ID for RS485 and CAN (Controller from the bottom) RS232: 9.6kBaud, use 1:1 connection cable to PC RS485 and CAN needs external termination (see manual) NTI AG Installation: E1000/E2000/E4000 series / 16.09.2005 Page 7/12...
Page 8
Optical isolated inputs Input voltage: 0 …. 24V for logical zero < 2V for logical one > 3.5V Input current: < 20 mA (internally limited to 20 mA) Update rate: 1.6 ms NTI AG Installation: E1000/E2000/E4000 series / 16.09.2005 Page 8/12...
Controller Series E1000/2000/4000 Mechanical Dimension Dimensions Fixings for 2 x M5 screws Centers Recommended mounting for multiple controller installation Fixings for 2 x M5 screws Dimensions in mm NTI AG Installation: E1000/E2000/E4000 series / 16.09.2005 Page 9/12...
LED is ON l LED blinks shortly (ca. ¼s) off LED is OFF n LED blinks longer (ca. 1½s) Contact Addresses NTI AG LinMot Tel. +41 (0)56 419 91 91 Haerdlistrasse 15 Fax.