Chapter 4 Run and operation explanation for inverter

4.1 Run of inverter

4.1.1 Running order channels
ED300 Inverter has 3 kinds of order channels for controlling run
action of the inverter such as run、stop、jog etc.:
Operation Panel(Keypad)
Control by keys
Control terminal
Use control terminal FWD、REV、COM to make double-line control, or use
one of the terminals of DI1~DI6 and FWD or REV to make of 3-line
control
Serial Port
Control run or stop of the inverter through upper machine or other devices which
can communicate with the inverter
Choose order channel by setting function code P006
4.1.2 Frequency-provision channels
Under ED3000 common run mode there are 10 kinds of provision channels:
0: keypad analogy POT provision
1: Digital setting 1 keypad
2: Digital setting 2 terminal UP/DOWN provision
3: Analog voltage value AI1 provision
4: Analog current value AI2 provision
5: Terminal pulse provision
6: Analog AI1+AI2 value combination provision
7: Analog AI1-AI2 value combination provision
8: Analog AI1+(AI2-10mA) value combination provision
9: PC serial port provision
4.1.3 Word State
Work states of ED3000 are classified as Waiting State, Running State,
Programmed State and Malfunction Alert State:
waiting State: If there is no running command after the inverter
electrified or after stop command during running state, the inverter
enters into waiting state
running State: Received run command, the inverter enters into running
state
programming state: By operating keypad, modify and set the function
STOP
RUN
JOG
RESE T
on keypad to run or stop the motor
provision