3.1 Installation ambient

3.1.1 Demand for installation ambient
(1) Installed in drafty indoor place, ambient temperature within -10ºC~40ºC,need
external compulsory heat sink or reduce the volume if temperature exceeds
40ºC.
(2) Avoid installing in place with direct sunlight, much dust, floating fibre and metal
powder.
(3) Forbid to install in place with corrosive, explosible gas.
(4) Humidity should be smaller than 95%RH,without condensation water.
(5) Installed in place of plane fixing vibration smaller than 5.9m/s
(6) Keep away from electromagnetic disturbance source and other electronic
apparatus sensible to electromagnetic disturbance.
3.1.2 Installation direction and space
(1) Normally the inverter should be mounted vertically.
(2) Demand for minimum mounting space and distance, please see Fig.3-1.
(3) When install multiple inverters up and down, must apply leading divider between
them, see fig.3-2.

Chapter 3 Installation and wiring

- -
18
2
(0.6g).
导流隔板