ED3000 系列高性能通用变频器使用说明书
Fig. 3-1 mounting space
3.2 Key board disassembly and installation
Disassembly: Let the forefinger press finger inlet on the keypad, depress fixing
flexible plate on the top lightly, draw it outward, then you can disassemble the
keypad.
Assembly: Place the fixing hook at the bottom of keypad onto mounting claw
on keypad mounting hole, let forefinger press fixing flexible plate on top of keypad
and then push it inside, release it in proper location.

3.3 wiring notice points

(1) Assure power cut off completely for above 10 minutes before wiring, otherwise have
danger of getting electric shock.
(2) Forbid connecting power wire to output U, V, W of the inverter.
(3) There is current leakage in the inverter, for safety reason, inverter and motor must be
earthed safely, commonly use 3.5 mm
resistance smaller than 10Ω.
(4) Before shipment compression resistance test of the inverter is passed, so user should not
conduct compression resistance test again.
(5) Should not assemble electromagnetic contactor and absorbing capatance or other
absorbing device, see fig.3-3.
(6) To be convenient to over current protect of input side and power off maintenance inverter
should be connected to power supply through relay.
(7) Connecting wire for relay input and output loop(DI1~DI6、 DO1、 DO2), should use above
0.75mm² glued wire or shielding wire, one shielding layer end hung in the air, the other
connected to grounding end E, connecting wire shorter than 50m.
fig. 3-2 mounting of multiple inverters
2
above copper wire as ground wire and ground
- -
19