CERAMIC RADIANT HEATERS
Pressure regulation
Important:
before first startup you need to check if the gas pressure is proper as it is written on rating
plate. you need to behave according to instruction below:
1. Unscrew a bolt of electric valve (PO) and put in proper manometer.
2. Remove hood from pressure regulator (R), and turn to time when value of pressure
will be the same as it is written on rating plate
3. Screw out manometer and screw in a bolt
4. Cover a regulator (R) by a hood and tighten it.
direction of gas flow
Exchange nozzles
All our devices are tested with natural gas methane or liquid gas before realization an order
Pressure characteristic and type of gas using during test are always written on rating plate
located on radiator in visible place.
In case when feeding gas is different you need to order supplementary suite of exchanging
nozzles, given model of radiator and type of gas. Exchange nozzles must be made by trained
representatives.
EN.SBC_v2_1 Feb 2019
Promienniki Gazowe
direction of gas flow
Pic. 7.
.
Sp. z o.o
16