Download Print this page
Hussmann IMPACT LW Technical Data Sheet

Hussmann IMPACT LW Technical Data Sheet

Hussmann impact lw: data sheet
Hide thumbs Also See for IMPACT LW:

Advertisement

C
B
We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
Item Part #
Description
F
A
T
AN
SSEMBLIES AND
HERMOSTATS
A. 4W Fan Assembly
0392457
Fan Motor, Standard (MO.4410101)
0409511
Fan Blade, embossing toward motor
(FB.0409511)
B. Optional Adjustable Refrigeration Thermostat
C. 0398557
Defrost Termination Thermostat
(Front)
(CT.4440611)
0398558
(Electric Defrost only)
(Rear)
D. 0425304
Heater Switch
(Koolgas Defrost only)
(CT.0425304)
NOTE: Revision G corrects heater data on Page 4.
©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
®
Merchandisers
C
A
D
Wiring Item #
(CT.4481088)
E
F
Item Part #
H
EATERS
(1)
E. 0395709
F. Drip Pan Heaters, Electric 208V
(2)
0392413
0392414
(3)
Drip Pan Heaters, Koolgas 120V
0421238
0421239
(4)
G. Nosing Anti-sweat Heaters
0401605
0401557
0401606
0401558
Technical Data Sheet
P/N 0395737_G
NSF
®
Certified
February 2007
G
D
Description
Wiring Item #
Modular Electric
Defrost Heaters, 208V
(HE.4850409)
8 foot case (HE.0392413)
12 foot case (HE.0392414)
8 foot case (HE.4850496)
12 foot case (HE.4850497)
8 foot case (Discharge) (HE.0401605)
8 foot case (Return) (HE.4850467)
12 foot case (Discharge)
(HE.4850471)
12 foot case (Return) (HE.4850468)
P/N 0395737_G
LW
(5)
(6)
(7)
(8)

Advertisement

loading

Summary of Contents for Hussmann IMPACT LW

  • Page 1 Heater Switch (Koolgas Defrost only) (CT.0425304) NOTE: Revision G corrects heater data on Page 4. ©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM ® Wiring Item # Item Part # EATERS E.
  • Page 2: Plan Views

    (H) LH end of case to center of LH front and rear refrigeration outlets Back O/S of case to center of refrigeration outlet (I) Center of refrigeration outlet to O/S edge of front skidrail 2 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Dimensions shown as inches & (mm). (141) (276)
  • Page 3 These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF ) Standard #7 requirements. ® P/N 0395737_G HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM Impact Frozen Food & Ice Cream REFRIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75°F and...
  • Page 4: Electrical Data

    Export Rear Compartment Koolgas Drip Pan Heaters 120V 60Hz Standard 230V 50Hz Export Standard Lighting None 4 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. 8 ft 12 ft Amperes 8 ft 12 ft 1.24 1.86 0.60 0.90 0.72 1.08 0.56...
  • Page 5 Termination Thermostat All components must have mechanical ground, and the merchandiser must be grounded. P/N 0395737_G HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM Electric Defrost – Standard 208 V Power From Defrost Contactors Drip Pan Heater Modular Electric Defrost Heaters...
  • Page 6 Drip Pan Heater Yellow Heater Switch 120V POWER All components must have mechanical ground, and the merchandiser must be grounded. 6 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Gas Defrost – Optional Fans Nosing (anti-sweat) Heaters Fans Nosing (anti-sweat) Heaters...