Preparation Of Cabinet For Operation; Removing Cabinet From Skid; Leveling Cabinet; Shelf Installation - Hussmann ARL Installation And Operation Manual

Arv, arl series
Hide thumbs Also See for ARL:
Table of Contents

Advertisement

PREPARATION OF CABINET FOR OPERATION

Removing Cabinet From Skid

Move the merchandiser as close as possible to its permanent location and remove hold-down brackets at the
front and rear of the cabinet. Check refrigeration lines to see that they are "free" and no damage has
occurred during shipping. Check fan blades for free operation.

Leveling Cabinet

These merchandisers must be installed level (front to back and end to end) to permit maximum draining of
the condensate water as well as proper door alignment and operation.
The merchandiser has been shipped with adjustable cabinet levelers installed. Level the unit by placing a
level on the merchandiser and adjust as required.

Shelf Installation

After the cabinet has been leveled and is in its final position, the shelves may be installed. Shelf spacing is
adjustable by positioning the shelf supports according to your loading requirements.
WARNING
(Low Temp. Models) Do NOT place product directly on floor of merchandiser. Locate bottom shelf in the
lowest position to the floor of the merchandiser (approximately 2" [5 cm] off bottom) before loading.
Failure to comply may result in product loss.
Display
Serial Plate
Shelves
Door
Front of Merchandiser
Front Grill