ARV & ARL SERIES Merchandisers Medium Temperature & Low Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT Installation & Operation Manual Shipped With Case Data Sheets P/N 2400134E ARV, ARL Series DECEMBER,2000 HUSSMANN -CORPORATION Hussmann Monterrey Mexico Carretera Mexico-Laredo KM. 1009...
Table of Contents SHIPPING DAMAGE General Apparent Loss or Damage Concealed Loss or Damage Location PREPARATION OF CABINET FOR OPERATION Removing Cabinet from Skid Leveling Cabinet Shelf Installation Door seal Fan Cycle Switch Lamps Sealing case to floor EXTERIOR DIMENSION Exterior Dimensions Refrigeration system Description...
P/N 2400134E SHIPPING DAMAGE General All equipment should be thoroughly examined for shipping damage before and during unloading. This equipment has been carefully inspected at our factory and the carrier has assumed responsibility for safe arrival. If damaged, either apparent or concealed, claim must be made to the carrier. Apparent Loss Or Damage If there is an obvious loss or damage, it must be noted on the freight bill or express receipt and signed by the carrier's agent;...
PREPARATION OF CABINET FOR OPERATION Removing Cabinet From Skid Move the merchandiser as close as possible to its permanent location and remove hold-down brackets at the front and rear of the cabinet. Check refrigeration lines to see that they are "free" and no damage has occurred during shipping.
Door seal (closing mechanisms). -Hinged Doors. Check to ensure the door torque is capable of closing the door automatically. Open the door 45 degrees and release it, the door should close and seal. To adjust the torque, place a wrench on each of the 2 nuts located on the bottom hinge. Hold the top wrench firmly and loosen the bottom nut.
Page 6
ARV/ARL WITH HINGED DOORS 28 1/4" 28 1/4" 30 1/4" 70 3/4" 3 0 0 4 0 0 5 0 0 Features ARV-300 ARV-400 Doors Cu. Ft Capacity 17.6 Shelves Features ARL-300 ARL-400 Doors Cu. Ft Capacity 17.6 Shelves S pecifications subject to change without notice.
REFRIGERATION SYSTEM Description All upright merchandisers are equipped with a hermetic or semi-hermetic compressor. The condenser is fin and tube construction. The air is taken in at the front of the cabinet through the lower grill and discharged out by the back of the cabinet. A crankcase pressure regulating valve is utilized on some low temperature models.
START UP / OPERATION Electrical Supply WARNING Equipment MUST be GROUNDED! Wiring of the unit is complete when it is shipped from the factory. The unit is supplied with a three conductor electrical cord which extends from the rear of the unit. Plug the unit into correct grounded outlet. It is recommended that a separate circuit be run for each cabinet to prevent the possibility of another appliance blowing a fuse, causing subsequent loss of product.
NOTE: Evaporator fan will cycle "OFF" during defrost cycle. Evaporator fan will delay approximately 5 to 10 minutes after each defrost cycle and initial start-up on Low Temperature Models (ARL's). Merchandiser Electrical Data Merchandiser data sheets are attached to the back of this manual.