Hussmann ARL Installation And Operation Manual

Hussmann ARL Installation And Operation Manual

Arv, arl series
Hide thumbs Also See for ARL:

Advertisement

R
ARV & ARL SERIES
Merchandisers
Medium Temperature
& Low Temperature
Merchandisers
PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT
Installation &
Operation Manual
Shipped With Case Data Sheets
P/N 2400134E
ARV, ARL Series
DECEMBER,2000
HUSSMANN -CORPORATION
Hussmann Monterrey Mexico
Carretera Mexico-Laredo KM. 1009
Cienega de Flores, Nuevo Leon 65550
MEXICO
Phone: (52) 81-8318-6400
Fax: (52) 81-8318-6496

Advertisement

Table of Contents
loading

Summary of Contents for Hussmann ARL

  • Page 1 ARV & ARL SERIES Merchandisers Medium Temperature & Low Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT Installation & Operation Manual Shipped With Case Data Sheets P/N 2400134E ARV, ARL Series DECEMBER,2000 HUSSMANN -CORPORATION Hussmann Monterrey Mexico Carretera Mexico-Laredo KM. 1009...
  • Page 2: Table Of Contents

    Table of Contents SHIPPING DAMAGE General Apparent Loss or Damage Concealed Loss or Damage Location PREPARATION OF CABINET FOR OPERATION Removing Cabinet from Skid Leveling Cabinet Shelf Installation Door seal Fan Cycle Switch Lamps Sealing case to floor EXTERIOR DIMENSION Exterior Dimensions Refrigeration system Description...
  • Page 3: Shipping Damage

    P/N 2400134E SHIPPING DAMAGE General All equipment should be thoroughly examined for shipping damage before and during unloading. This equipment has been carefully inspected at our factory and the carrier has assumed responsibility for safe arrival. If damaged, either apparent or concealed, claim must be made to the carrier. Apparent Loss Or Damage If there is an obvious loss or damage, it must be noted on the freight bill or express receipt and signed by the carrier's agent;...
  • Page 4: Preparation Of Cabinet For Operation

    PREPARATION OF CABINET FOR OPERATION Removing Cabinet From Skid Move the merchandiser as close as possible to its permanent location and remove hold-down brackets at the front and rear of the cabinet. Check refrigeration lines to see that they are "free" and no damage has occurred during shipping.
  • Page 5: Door Seal

    Door seal (closing mechanisms). -Hinged Doors. Check to ensure the door torque is capable of closing the door automatically. Open the door 45 degrees and release it, the door should close and seal. To adjust the torque, place a wrench on each of the 2 nuts located on the bottom hinge. Hold the top wrench firmly and loosen the bottom nut.
  • Page 6 ARV/ARL WITH HINGED DOORS 28 1/4" 28 1/4" 30 1/4" 70 3/4" 3 0 0 4 0 0 5 0 0 Features ARV-300 ARV-400 Doors Cu. Ft Capacity 17.6 Shelves Features ARL-300 ARL-400 Doors Cu. Ft Capacity 17.6 Shelves S pecifications subject to change without notice.
  • Page 7: Refrigeration System

    REFRIGERATION SYSTEM Description All upright merchandisers are equipped with a hermetic or semi-hermetic compressor. The condenser is fin and tube construction. The air is taken in at the front of the cabinet through the lower grill and discharged out by the back of the cabinet. A crankcase pressure regulating valve is utilized on some low temperature models.
  • Page 8: Start Up / Operation

    START UP / OPERATION Electrical Supply WARNING Equipment MUST be GROUNDED! Wiring of the unit is complete when it is shipped from the factory. The unit is supplied with a three conductor electrical cord which extends from the rear of the unit. Plug the unit into correct grounded outlet. It is recommended that a separate circuit be run for each cabinet to prevent the possibility of another appliance blowing a fuse, causing subsequent loss of product.
  • Page 9: Maintenance

    NOTE: Evaporator fan will cycle "OFF" during defrost cycle. Evaporator fan will delay approximately 5 to 10 minutes after each defrost cycle and initial start-up on Low Temperature Models (ARL's). Merchandiser Electrical Data Merchandiser data sheets are attached to the back of this manual.

Table of Contents