Hussmann ASC-LG Installation And Operation Manual

Hussmann ASC-LG Installation And Operation Manual

Lift-up curved glass, refrigerated service gelato and ice cream case

Advertisement

Quick Links

ASC-LG / ASCS-LG
Lift-up Curved Glass, Refrigerated
Service Gelato and Ice Cream Case
ASC-LG / ASCS-LG-0506
INSTALLATION & OPERATION GUIDE

Advertisement

Table of Contents
loading

Summary of Contents for Hussmann ASC-LG

  • Page 1 ASC-LG / ASCS-LG Lift-up Curved Glass, Refrigerated Service Gelato and Ice Cream Case ASC-LG / ASCS-LG-0506 INSTALLATION & OPERATION GUIDE...
  • Page 2: Table Of Contents

    (909) 628-8942 FAX (909) 590-4910 (800) 395-9229 General Instructions THIS BOOKLET CONTAINS INFORMATION ON: ASC-LG / ASCS-LG Lift-up curved and straight glass refrigerated service Gelato and Ice Cream Merchandiser SHIPPING DAMAGE All equipment should be thoroughly examined for shipping damage before and during unloading.
  • Page 3: Cut & Plan Views

    Rev. 0506 Lights (T-8) optional pans " " " ASC-LG Gelato Service Case Scale = 1/2" Lights (T-8) optional pans " ASCS-LG Gelato Service Case With Straight Glass Option Scale = 1/2" LOCATION The refrigerated merchandisers have been designed for use only in air conditioned stores where tempera- ture and humidity are maintained at or below 75°F and...
  • Page 4: Lift-Up / Tilt-Out Glass -Where Applicable

    After cases have been leveled and joined, and refrig- eration, electrical, and wasted piping work completed, install the splashguards. Fasten along the top edge, or center, with #10 X 3/3” sheet metal screws. ASC-LG / ASCS-LG-0506 oiNt loor GLASS BREAKAGE...
  • Page 5: Plumbing

    Rev. 0506 WASTE OUTLET AND P-TRAP The waste outlet is located off the center of the case on one side allowing drip piping to be run lengthwise under the fixture. A 1-1/2” P-trap and threaded adapter are supplied with each fixture. The P-trap must be installed to prevent air leakage and insect entrance into the fixture.
  • Page 6: T-Stat Location

    PIPING The refrigerant line outlets are located under the fixture at the left end when viewed from the back. Insulate suction lines to prevent condensation dripping on the floor. ASC-LG / ASCS-LG-0506 Standard Case T-Stat Location Ballasts Gelato Case T-Stat Location...
  • Page 7: Paragon Erc 2 Programming / Settings Instructions

    Rev. 0506 Paragon ERC 2 Programming / Settings Instructions...
  • Page 8 ASC-LG / ASCS-LG-0506 Paragon ERC 2 Programming / Settings Instructions Cont’d...
  • Page 9 Rev. 0506 Paragon ERC 2 Programming / Settings Instructions Cont’d...
  • Page 10 ASC-LG / ASCS-LG-0506 Paragon ERC 2 Programming / Settings Instructions Cont’d...
  • Page 11: Electrical

    Actual ampere draw may be less than specified. Field wiring from the refrigera- tion control panel to the merchandisers is required for refrigeration thermostats. Most component amperes are listed in the “Case Specs” section, but always check the serial plate.
  • Page 12: User Information

    Hussmann cases were not designed to “heat up” or “cool down” product—but rather to maintain an item’s proper temperature for maximum shelf life.
  • Page 13: Non-Glare Glass Cleaning

    User Information, Cont’d CLEANING Hussmann recommends using a clean damp cham- ois, or a paper towel marked as dust and abrasive free with 210 ® by calling Sumner Labs at 1-800-542-8656. Hard, rough cloths or paper towels will scratch the acrylic and should not be used.
  • Page 14: Maintenance

    COPPER COILS The copper coils used in Hussmann merchandisers may be repaired in the field. Materials are available from local refrigeration wholesalers. Hussmann recommends using #15 Sil-Fos for re- pairs.
  • Page 15: Glass Adjustment And Replacement

    Rev. 0506 GLASS REPLACEMENT AND ADJUSTMENT INSTRUCTIONS In order to replace or adjust the glass, the glass must be placed in the raised position. The underside of the clamp is exposed, revealing the tightening screws. By turning these screws counterclockwise 1/4 turn each, the glass will be loosened for either removal or adjustment.
  • Page 16: Electrical And Refrigeration Specifications

    -5° 10° 5° 8’ 5,200 -5° 10° 5° 10’ 6,500 -5° 10° 5° 12’ 7,800 -5° 10° 5° ASC-LG / ASCS-LG (Ice Cream) 4’ 1,800 -30° -10° -20° 6’ 2,700 -30° -10° -20° 8’ 3,600 -30° -10° -20° 10’ 4,500 -30°...
  • Page 17: Electrical Schematics

    Rev. 0506 + _ SENSOR Electrical Schematics LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST...
  • Page 18 Electrical Schematics (Cont.) 120V 240V LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST ASC-LG / ASCS-LG-0506...
  • Page 19 Rev. 0506 Electrical Schematics (Cont.) + _ SENSOR 125-01-3266 125-01-3266 125-01-3266 125-01-3266 LH3-120-L FULHAM BALLAST LH3-120-L FULHAM BALLAST LH3-120-L FULHAM BALLAST LH3-120-L FULHAM BALLAST...
  • Page 20 Electrical Schematics (Cont.) 120V 240V LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST ASC-LG / ASCS-LG-0506...
  • Page 21 Rev. 0506 120V 240V Electrical Schematics (Cont.) LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST...
  • Page 22 Electrical Schematics (Cont.) 125-01-#### HEATER SWEEP LH3-120-L 125-01-3266 LH3-120-L 125-01-3266 LH3-120-L 125-01-3266 125-01-0096 5320-W LEVITON RECEPTACLE DUPLEX ASC-LG / ASCS-LG-0506 FULHAM BALLAST FULHAM BALLAST FULHAM BALLAST...
  • Page 23 Rev. 0506 Electrical Schematics (Cont.) 125-01-#### HEATER SWEEP LH6-120-L FULHAM 125-01-3279 BALLAST LH6-120-L FULHAM 125-01-3279 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST 125-01-0096 5320-W LEVITON RECEPTACLE DUPLEX...
  • Page 24 Electrical Schematics (Cont.) 125-01-#### #### HEATER SWEEP LH3-120-L 125-01-3266 LH3-120-L 125-01-3266 LH3-120-L 125-01-3266 LH3-120-L 125-01-3266 125-01-0096 5320-W LEVITON RECEPTACLE DUPLEX ASC-LG / ASCS-LG-0506 FULHAM BALLAST FULHAM BALLAST FULHAM BALLAST FULHAM BALLAST...
  • Page 25 Rev. 0506 Electrical Schematics (Cont.) 125-01-#### HEATER SWEEP LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST 125-01-0096 5320-W LEVITON RECEPTACLE DUPLEX...
  • Page 26 Electrical Schematics (Cont.) 125-01-#### HEATER SWEEP LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST 125-01-0096 5320-W LEVITON RECEPTACLE DUPLEX ASC-LG / ASCS-LG-0506...
  • Page 27 Rev. 0506 Electrical Schematics (Cont.) 120V 240V LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST...
  • Page 28 Electrical Schematics (Cont.) 120V 240V LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST ASC-LG / ASCS-LG-0506...
  • Page 29 Rev. 0506 Electrical Schematics (Cont.) 120V 240V LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST...
  • Page 30 Electrical Schematics (Cont.) 120V 240V LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST ASC-LG / ASCS-LG-0506...
  • Page 31 Rev. 0506 Electrical Schematics (Cont.) 120V 240V LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST...
  • Page 32 ASC-LG / ASCS-LG-0506 Electrical Schematics (Cont.) LH3-120-L FULHAM 125-01-3266 BALLAST...
  • Page 33: Appendices

    The installer is responsible for following the instal- Appendices lation instructions and recommendations provided by Hussmann for the installation of each individual type refrigerator. Refrigeration piping should be sized according to Hussmann’s equipment recommendations and installed in accordance with normal refrigeration practices.
  • Page 34: Appendix D. - Recommendations To User

    CFC-12, CFC-502 or other refrigerant? If so, have the modifications been made in accordance with the recommendations of Hussmann’s equipment ? Is the refrigerator charged with the proper refrigerant and lubri- cant? Does the system use the recommended compressor? APPENDIX D.
  • Page 35: Warranty

    Load levels as defined by Hussmann must be observed. The best preservation is achieved by following these rules: a) Buy quality products.
  • Page 36 The MODEL NAME and SERIAL NUMBER is required in order to provide you with the correct parts and information for your particular unit. They can be found on a small metal plate on the unit. Please note them below for future reference. MODEL: SERIAL nuMBER: ASC-LG / ASCS-LG-0506...