Hussmann impact excel d5xrris: data sheet (7 pages)
Summary of Contents for Hussmann 10HD
Page 1
First Call for help (US and Canada): 1-800-922-1919 Soporte Tècnico y Asistencia (Mèxico): 01-800-522-1900 For a Service Network Locator and other www.hussmann.com HUSSMANN - GLOVERSVILLE INSTRUCTIONS HD – HS – HDF-8 Information visit us at select Worldwide Locations P/N OII – HD-HS-8HDF...
Introduction Inspection Base, Exterior Shell, Interior Liner, Sub-top, Insulation and Main Top Condensing Unit Cabinet Dimensions, Electrical, and Capacity Installation and Start Up Temperature Control and Defrosting Cleaning Condenser Cleaning Exterior Cleaning Interior Trouble Shooting Chart Lid Gasket Replacement Main Top Heater Replacement TABLE OF CONTENTS Page 7 &...
INTRODUCTION – The HS and HD models have been designed to give maximum performance with minimum energy consumption. They have the versatility in product temperature range to be used for storage at sub zero to dipping at desired above zero tempera- tures.
CONDENSING UNIT – All models incorporate a slide-out condensing unit for eas y access to all com- ponents. All have a bare tube condenser design to minimize field maintenance. CABINET DIMENSIONS, ELECTRICAL DATA, CABINET CAPACITIES OUTSIDE Cabinet Length Width 2-HS 30 1/2 19 7/16 4-HD...
INSTALLATION and START UP LEVELING – Level case front to back and end to end, shimming where necessary upon in- stallation to assure proper operation of drains and refrigeration systems. PLUMBING – To simplify cleaning and for sani- tary purposes, we s uggest that a connec- tion be made from the cabinet drain tube to a floor drain.
CONDENSING UNIT – The condens ing unit is mounted on a slide-out base, accessible by removing the access panel. The condenser is of the bare- tube des ign. The condenser fan motor draws air through the condenser and passes over the condenser for its cooling and it is expelled out the back of the unit compartment.
TROUBLE Compressor will not start, no noise Compressor will not cuts out on overload High head pressure TROUBLE SHOOTING CHART PROBABLE CAUSE 1. Power disconnected 2. Blown fuse or breaker 3. Defective or broken wiring 4. Defective overload 5. Defective temperature 1.
Warm storage temperatures 1. Temperature control not Compressor runs continuously – product too cold Compressor runs continuously – product too warm LID GASKET REPLACEMENT – Remove lids Grasp the bottom of the gasket with the fingers and pull outward Work the bottom of gasket from the retainer all around the perimeter openings. Lift up the gasket and remove the phillips head screws holding the retainer in place.
Install gasket on retainer and insert in opening. Putting downward pressure on gasket-retainer. Reinstall phillips head screws Stretch gasket downward and install gasket bottom flange over retainer flange. HOW TO REPLACE HEATERS – Disconnect power to cabinet, remove collar as shown. Lift off collar and retainer, being careful not to put stress on the heater connections.
Page 11
HEATER CONNECTOR WIRES POWER CORD 115V 60 HZ 1 PH HIGH TEMP. PRESSURE CONTROL CONTROL COND. START CAP. TAP CONNECTORS MATERIAL: XXXXXX-XX SIZE XXXXXXXXXX XX/XX/XX XXXX DIE NO. REV. DATE E.C.N. COMPRESSOR OVERLOAD RELAY HD-10, R-404A SHEET TOLERANCES UNLESS OTHERWISE SPECIFIED. SIZE FRACTIONAL 1/32"...
Page 12
HEATER CONNECTOR WIRES POWER CORD 115V 60 HZ 1 PH TEMP. CONTROL COND. START CAP. TAP CONNECTORS MATERIAL: XXXXXX-XX SIZE XXXXXXXXXX XX/XX/XX XXXX DIE NO. REV. DATE E.C.N. XXXX-XXXX COMPRESSOR MOTOR OVERLOAD RELAY COMPRESSOR HD-6, R-404A SHEET TOLERANCES UNLESS OTHERWISE SPECIFIED. SIZE FRACTIONAL 1/32"...
Page 13
TEMP. CONTROL POWER CORD 115V 60 Hz 1 PH OVERLOAD RELAY COND. START CAP. REV EO # REV DATE REV BY TOLERANCES UNLESS OTHERWISE SPECIFIED: FRACTIONAL 1/32" DECIMAL 0.031" ANGULAR 1° HOLE LOCATION & SPACING 1/64" APPROVED BY EO NUMBER DRAWN BY: DATE DRAWN : APPROVED BY:...
Page 14
HEATER CONNECTOR WIRES GRND POWER CORD 115V 60 Hz 1 PH TEMP. CONTROL COND START CAP. TAP CONNECTORS REV EO # REV DATE REV BY APPROVED BY COMPRESSOR OVERLOAD RELAY COMPRESSOR HD-8, HDF-8 (R-404A) TOLERANCES UNLESS OTHERWISE SPECIFIED: FRACTIONAL 1/32" DECIMAL 0.031"...
Need help?
Do you have a question about the 10HD and is the answer not in the manual?
Questions and answers