Hotpoint NVLR223EG Dimension Manual page 2

5.8 cu. ft. extra-large capacity electric dryer
Hide thumbs Also See for NVLR223EG:

Advertisement

GE Dryer Vent
GE Dryer Vent
NVLR223EG – Hotpoint 5.8 Cu. Ft. Extra-Large Capacity Electric Dryer
Dryer Exhausting Information – Use Metal Duct Only
Vertical and Horizontal Ducting
Best Performance
Maximum Length of 4" Dia.
Rigid Metal Duct
A
A
Exhaust Hood Type
A
4
Number
B
4
B
of
A
Domestic
90°
4" Opening
2-1/2"
2-1/2
Dryer Models
Turns
Opening
2-1/2
0
90 ft.
65 ft.
1
60 ft.
45 ft.
7.0, 6.0 and 5.8
2
45 ft.
35 ft.
Capacity Models
3
35 ft.
25 ft.
all Electric Dryers
4
25 ft.
15 ft.
0
90 ft.
60 ft.
7.0, 6.0 and 5.8
1
60 ft.
45 ft.
Capacity Models
2
45 ft.
35 ft.
all Gas Dryers
3
35 ft.
25 ft.
Spacemaker
Models
®
DSKS433EB
0
46 ft.
37 ft.
DSKS333EC
1
38 ft.
30 ft.
DSKP333EC
2
31 ft.
22 ft.
WSM2780H
3
24 ft.
15 ft.
Spacemaker Model
0
56 ft.
42 ft.
1
46 ft.
36 ft.
2
34 ft.
28 ft.
WSM2700H
3
32 ft.
18 ft.
Spacemaker Models
0
43 ft.
36 ft.
WSM2420D
1
33 ft.
26 ft.
WSM2480D
2
23 ft.
16 ft.
Specification Revised 12/06
470150
Maximum Length of 4" Dia.
Flexible Metal Duct
Exhaust Hood Type
B
A
B
4" Opening
2-1/2"
Opening
55 ft.
45 ft.
40 ft.
30 ft.
30 ft.
20 ft.
20 ft.
15 ft.
15 ft.
10 ft.
55 ft.
45 ft.
40 ft.
30 ft.
30 ft.
20 ft.
20 ft.
15 ft.
30 ft.
24 ft.
25 ft.
20 ft.
20 ft.
14 ft.
16 ft.
10 ft.
30 ft.
22 ft.
22 ft.
14 ft.
16 ft.
10 ft.
10 ft.
5 ft.
30 ft.
24 ft.
24 ft.
18 ft.
16 ft.
10 ft.
Dryer exhausting information
For complete information see installation instructions packed with dryer.
Important note:
5.8 cu. ft., 6.0 cu. ft. and 7.0 cu. ft. dryers do not require additional parts to convert to bottom
or side venting. Unitized models do not require a kit for side venting.
Ducting materials
For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If "all rigid
metal" duct cannot be used, then "flexible all metal" venting can be used, but it will reduce the maximum
recommended duct length. The following kit or parts are available from your local service organization.
Kit WX8X75 – 7' aluminum duct and 4' hood, short tail.
(OR individual parts):
WX8X65 7' aluminum flex duct only
WX8X58 4' clamps (2)
WX8X67 4' exhaust hood
See installation instructions for complete information.
Exhaust length calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of
dryer, add one turn.
2. The maximum length of 4' rigid (aluminum or galvanized) duct which can be tolerated is shown in the
table. The maximum lengths for flexible ducts are less than for rigid duct.
See table in installation instructions. A turn of 45° or less may be ignored. Two 45° turns within the duct
length should be treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.
Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture
and lint from being blown into the room. Gas dryers or any dryer located in a closet must be exhausted to
the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor
(crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause
damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the
combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The
wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed
down. Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a
4" opening dampered wall cap.
Listed by