Main Parts Component - Hitachi RAS-E08H2A Service Manual

Table of Contents

Advertisement

MAIN PARTS COMPONENT

THERMOSTAT
Thermostat Specifications
MODEL
THERMOSTAT MODEL
OPERATION MODE
TEMPERATURE
°C (°F)
FAN MOTOR
Fan Motor Specifications
MODEL
POWER SOURCE
OUTPUT
CONNECTION
BLU : BLUE
GRY : GRAY
BLK : BLACK
MAIN ELECTRIC COMPONENTS FOR OUTDOOR UNIT
NAME
REVERSING VALVE COIL
REACTOR L1
REACTOR L2
FILM CAPACITOR
ON
INDICATION
16
OFF
ON
INDICATION
24
OFF
ON
INDICATION
32
OFF
RAS-E08H2A, RAS-E10H2A
35V
0V
5V
0 - 5V
FG
(Control circuit built in)
YEL : YELLOW
ORN : ORANGE
PNK : PINK
RATING
135 Ω (20 ˚C)
13 (mH), 0.224 Ω
25.5 (mH), 0.37 Ω
45 (μF)
– 17 –
RAS-E08H2A, RAS-E10H2A
COOL
16.7 (62.1)
16.0 (60.8)
24.7 (76.5)
24.0 (75.2)
32.7 (90.9)
32.0 (89.6)
DC 5V, 35V
25W
RED
BLK
WHT
M
YEL
BLU
BRN : BROWN
GRN : GREEN
VIO : VIOLET
APPLICABLE MODELS
IC
HEAT
18.7 (65.7)
19.3 (66.7)
26.7 (80.1)
27.3 (81.1)
34.7 (94.5)
35.3 (95.5)
RAC-E08H2, RAC-E10H2
DC 140 - 350V
40W
140-
RED
350V
BLK
0V
WHT
15V
YEL
0-6V
BLU
0-15V
WHT : WHITE
RED : RED
RAC-E08H2, E10H2
RAC-E08H2, E10H2
RAC-E08H2, E10H2
RAC-E08H2, E10H2
M

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rac-e08h2Ras-e10h2aRac-e10h2

Table of Contents