House Disaster: Flood/Temp Range,
Honeywell-Compatible

Features

• Tri-Mode Environmental Sensing:
o Flood/Moisture Sensor
o Freeze – for Furnace Failure
o Overheat – for Furnace runaway or Air Conditioning failure.
• 3 unique wireless Loops: one for each function
• Cover tamper.
• Strong, reliable RF signal.
• 8-10 year battery life on CR123A battery.
• Low Battery indication.
• 3.3x1.4x1.1 inches.

Key Instructions

• Battery "+" faces towards spring.
• Enrolling:
Place Panel in Zone Programming mode.
Zone Type = for example, 24-Hr. Aux.
Input Type = Supervised RF Transmitter.
When asked for serial number, press Tamper switch.
Program the desired Loop number you want that zone to
monitor. Loop functions are:
• Loop 1: Overheat.
• Loop 2: Flood.
• Loop 3: Freeze.
• Loop 4: Tamper.
• Test Temp alarm functions by putting in a freezer, or blowing a hair dryer on
sensor.
• Test Flood alarm function by putting sensor in water (distilled water will not
work, but tap water should).
RE219_Honeywell_Flood_Temp_Instructions.docPage 1 of 4
www.ResolutionProducts.com

Operation

9/6/2011
• Flood – Loop 2:
Alarm: when liquid rises 0.040 inches above sensor bottom.
Tamper: when cover is opened.
Supervisory: every hour.
• Freeze – Loop 3
Alarm: when room temperature drops below 40F.
Tamper: when cover is opened.
Supervisory: every hour.
• Overheat – Loop 1
Alarm: when room temperature rises above 100F.
Tamper: when cover is opened.
Supervisory: every hour.
RE219_Honeywell_Flood_Temp_Instructions.docPage 2 of 4
www.ResolutionProducts.com
9/6/2011

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RE219 and is the answer not in the manual?

Questions and answers

Summary of Contents for Resolution Products RE219

  • Page 1 Security Operation Solutions • Flood – Loop 2: Alarm: when liquid rises 0.040 inches above sensor bottom. Tamper: when cover is opened. RE219 House Disaster: Flood/Temp Range, Supervisory: every hour. Honeywell-Compatible • Freeze – Loop 3 Features Alarm: when room temperature drops below 40F.
  • Page 2 100K-Ohm nominal (DO NOT use an EOL resistor) 0.04 inch floor spacing to eliminate floor Resolution Products, Inc. products will function with one of either GE, DSC or Honeywell systems. condensation falses. However, no Resolution product is produced by, endorsed by, nor is officially associated with GE, Checks moisture every 30 seconds Honeywell or DSC.

Table of Contents