Fujitsu AUY35UIA-LV Operating Manual

Fujitsu AUY35UIA-LV Operating Manual

Air conditioner compact cassette type

Advertisement

Quick Links

AIR CONDITIONER
Compact Cassette Type
KEEP THIS MANUAL FOR FUTURE REFERENCE
BEWAHREN SIE DIESES HANDBUCH ZUM SPÄTEREN NACHSCHLAGEN AUF
CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE
CONSERVE ESTE MANUAL PARA FUTURA REFERENCIA
CONSERVARE IL PRESENTE MANUALE PER FUTURE CONSULTAZIONI
ΦΥΛΑΞΤΕ ΤΟ ΕΓΧΕΙΡΙΔΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ
GUARDE ESTE MANUAL PARA REFERÊNCIA FUTURA
ХРАНИТЕ РУКОВОДСТВО ДЛЯ СПРАВОК В БУДУЩЕМ
BU KILAVUZU İLERİDE BAŞVURMAK ÜZERE SAKLAYIN
OPERATING MANUAL
BEDIENUNGSANLEITUNG
MANUAL DE FUNCIONAMIENTO
MANUALE DI ISTRUZIONI
ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
MANUAL DE FUNCIONAMENTO
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
KULLANIM KILAVUZU
MODE D'EMPLOI
[Original instructions]
PART No. 9374379712-02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AUY35UIA-LV and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fujitsu AUY35UIA-LV

  • Page 1 AIR CONDITIONER OPERATING MANUAL Compact Cassette Type BEDIENUNGSANLEITUNG MODE D’EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE FUNCIONAMENTO РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ KULLANIM KILAVUZU KEEP THIS MANUAL FOR FUTURE REFERENCE BEWAHREN SIE DIESES HANDBUCH ZUM SPÄTEREN NACHSCHLAGEN AUF CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE CONSERVE ESTE MANUAL PARA FUTURA REFERENCIA CONSERVARE IL PRESENTE MANUALE PER FUTURE CONSULTAZIONI...
  • Page 2: Table Of Contents

    OPERATING MANUAL PART No. 9374379712-02 AIR CONDITIONER (COMPACT CASSETTE TYPE) CONTENTS SAFETY PRECAUTIONS ........2 ADJUSTING THE DIRECTION OF AIR CIRCULATION ..11 FEATURES AND FUNCTIONS ....... 3 SWING OPERATION ..........11 NAME OF PARTS ........... 4 ECONOMY OPERATION ........12 PREPARATION ............6 10°C HEAT OPERATION ........
  • Page 3: Features And Functions

    FEATURES AND FUNCTIONS ■ Energy saving and Comfortable SLEEP TIMER function COOLING MODEL ● When the SLEEP timer button is pressed during cooling or INVERTER dry mode, the thermostat setting is gradually raised during the period of operation. When the set time is reached, the unit au- At the start of operation, large amount of power is used to tomatically turns off.
  • Page 4: Name Of Parts

    NAME OF PARTS Indoor unit 1 Air Filter (in air intake grille) 2 Airfl ow direction fl aps 3 Air intake grille 4 Control panel 5 Remote control signal receiver 6 MANUAL AUTO button When the MANUAL AUTO button is pressed in for more than ●...
  • Page 5 NAME OF PARTS Remote controller Display panel Display panel To facilitate explanation, the accompanying illustration has been drawn to show all possible indicators; in actual oper- ation, however, the display will only show those indicators appropriate to the current operation. 1 MODE button &...
  • Page 6: Preparation

    PREPARATION WARNING Load Batteries (R03/LR03 × 2) Take care to prevent infants and young ● children from accidentally swallowing the Press and slide the battery compartment lid on the batteries. reverse side to open it. CAUTION Slide in the direction of the arrow while pressing the mark.
  • Page 7: Operation

    OPERATION To Select Mode Operation Press the START/STOP button. The indoor unit’s OPERATION indicator lamp will light. The air conditioner will start operating. Press the MODE button to select the desired mode. Each time the button is pressed, the mode will change in the following order. AUTO COOL HEAT...
  • Page 8 OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). To Stop Operation Press the START/STOP button. The OPERATION indicator lamp will go out. MODE Operation AUTO (in COOLING model): When AUTO (automatic changeover) operation fi rst selected, the fan will ●...
  • Page 9: Timer Operation

    TIMER OPERATION Before using the timer function, be sure that the remote controller is set to the correct current time (☞ Page 6.) If the indoor unit is connected to a wired remote controller, the wireless remote controller cannot be used to set the timer. Note: In simultaneous multi connection, this function by using the wireless remote controller cannot be used.
  • Page 10: Sleep Timer Operation

    SLEEP TIMER OPERATION Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped. If the indoor unit is connected to a wired remote controller, the wireless remote controller cannot be used to set the sleep timer. Note: In simultaneous multi connection, this function by using the wireless remote controller cannot be used.
  • Page 11: Adjusting The Direction Of Air Circulation

    ADJUSTING THE DIRECTION OF AIR CIRCULATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Begin air conditioner operation before performing this procedure. Vertical Air Direction Adjustment Press the SET button (Vertical). Each time the button is pressed, the air direction range will change as follows: The remote controller’s display Attempting to move up/down air direc- ●...
  • Page 12: Economy Operation

    ECONOMY OPERATION Begin air conditioner operation before performing this procedure. To Use the ECONOMY Operation Indicator Lamp Press the ECONOMY button. The ECONOMY indicator lamp (green) will light. ECONOMY operation begins. To Stop the ECONOMY Operation :Lighting :OFF Press the ECONOMY button again. The ECONOMY indicator lamp (green) will go out.
  • Page 13: Selecting The Remote Controller Custom Code

    SELECTING THE REMOTE CONTROLLER CUSTOM CODE When two or more air conditioners are installed in a room and the Remote Controller is operating an air conditioner other than the one you wish to set, change the custom code of the Remote Controller to operate only the air conditioner you wish to set (4 selections possible).
  • Page 14: Cleaning And Care

    CLEANING AND CARE Before cleaning this product, be sure to turn it off and disconnect all the power supply. ● CAUTION The fan operates at high speed inside the unit, and could result in personal injury. ● Be careful not to drop the intake grille. ●...
  • Page 15: Troubleshooting

    CLEANING AND CARE Filter Reset (ECONOMY indicator lamp fl ashing/ A special setting) Can be used if set correctly during installation. ● Please consult authorized service personnel when using this function. • It lights on when it is time to clean the air fi lters. After turning the power on, press the MANUAL AUTO button for 2 seconds or less on the indoor unit.
  • Page 16 TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Symptom Problem See Page NORMAL Airfl ow is weak or When heating operation is started, fan speed is temporarily very low, to allow ● FUNCTION stops: internal parts to warm up.
  • Page 17: Operating Tips

    OPERATING TIPS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Heating Performance* Microcomputer-controlled Automatic Defrosting* This air conditioner operates on the heat-pump principle, ● When using the heating mode under conditions of low out- ●...
  • Page 18 OPERATING TIPS Multi-type Air Conditioner This indoor unit can be connected to a multi-type outdoor unit. The multi-type air conditioner allows multiple indoor units to be oper- ated in multiple locations. The indoor units may be operated simultaneously, in accordance with their respective output. Simultaneous Use of Multiple Units ❖...