Holux gm-83 engine board: specifications
Hide thumbs Also See for GM-83:

Advertisement

HOLUX
Technology,Inc.
8F, 26, Tai-Yuen Street, Tai-Yuen Hi-Tech
Industrial Park, Chu Pei City 302, Hsinchu, Taiwan.

Specifications

Snap Start
Hot Start
Warm Start
Cold Start
Satellite Reacquisition
Time Accuracy
Channels
Position Accuracy
Receiver
Protocol
Maximum Altitude
Maximum Velocity
Max. Update Rate
RF Connector
Dimension
Weight
Firmware Upgrade
Time Mark
Operating
Temperature
Storage Temperature
Operating Humidity
Electrical specifications:
Less than 75mA without antenna。
長天科技股份有限公司
新 竹 縣 竹 北 市 台 元 街 2 6 號 8 F
E-Mail:info@holux.com.tw Web: www.holux.com
< 3 sec (at < 25 minutes off period ).
8 sec(typ).
38 sec(typ).
45 sec(typ).
100 ms
12
25m CEP without SA
L1, C/A code
NMEA V2.2, 4800, 8, N, 1 or SiRF Binary
< 60,000 feet
< 700 knots
1 Hz
MCX or SMA
40.6(W) x 71.1(D) x 9.1(H) (mm) (The height of pin is excluded)
18g
Flash EPROM field programming software available
Output 1 pulse/sec, aligned with GPS time +-0.1 usec
-40
to +80
-45
to +100
5% to 95%, No Condensing
Tel:886 3 552 6268
Fax:886 3 552 6108

Advertisement