Siemens SIMATIC 6DL1193-6AR00-0AA0 Equipment Manual

Distributed i/o devices busadapter for distributed i/o

Advertisement

Quick Links

SIMATIC
Distributed I/O devices
BusAdapter for Distributed I/O
Equipment Manual
6DL1193-6AR00-0AA0; 6DL1193-6AG20-0AA0
6DL1193-6AG00-0AA0; 6DL1193-6AG40-0AA0
6DL1193-6AF00-0AA0
10/2021
A5E39261458-AC
Security information
Special conditions for safe
use of the BusAdapter
Preface
Installation
Behavior of the device name
Diagnostics
Pin assignments
Technical specifications
Contact
1
2
3
4
5
6
A
B
C

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC 6DL1193-6AR00-0AA0

  • Page 1 Security information Special conditions for safe use of the BusAdapter Preface SIMATIC Installation Distributed I/O devices BusAdapter for Distributed I/O Behavior of the device name Diagnostics Equipment Manual Pin assignments Technical specifications Contact 6DL1193-6AR00-0AA0; 6DL1193-6AG20-0AA0 6DL1193-6AG00-0AA0; 6DL1193-6AG40-0AA0 6DL1193-6AF00-0AA0 10/2021 A5E39261458-AC...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Security information..........................5 Special conditions for safe use of the BusAdapter ................7 Preface ..............................11 Installation............................13 Connections on the interface module and the BusAdapter ..........13 Useful information about the interface connection for communication ....... 13 Examples for the number of media interfaces ..............
  • Page 4 Table of contents SIMATIC BusAdapter BA LC/RJ45 (6DL1193-6AG20-0AA0) ........... 42 SIMATIC BusAdapter BA 2xLC (6DL1193-6AG00-0AA0)............43 SIMATIC BusAdapter BA LC/FC (6DL1193-6AG40-0AA0)............44 SIMATIC BusAdapter BA 2xFC (6DL1193-6AF00-0AA0)............45 Contact..............................47 Contact..........................47 Tables Table B-2 Derating when devices are used at an elevation above sea level ..........40 Table B-1 Climatic ambient conditions....................
  • Page 5: Security Information

    Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber...
  • Page 6 Security information BusAdapter for Distributed I/O Equipment Manual, 10/2021, A5E39261458-AC...
  • Page 7: Special Conditions For Safe Use Of The Busadapter

    Special conditions for safe use of the BusAdapter Enclosure required Observe the following: • The ambient conditions when using the distributed I/O system. • The requirements according to the standards applicable in the area of application: Area of application with validity of Requirement the standards EN / IEC 60529...
  • Page 8 Special conditions for safe use of the BusAdapter WARNING Safety functional extra low voltage Make sure that the supply and input voltages of the IO system are generated safely separately (Nominal value: 24 V DC +-20% Power supply according to the following standards: •...
  • Page 9 Special conditions for safe use of the BusAdapter WARNING Explosion hazard If the electric circuit is live, the following must be observed: • Do not disconnect the device in a flammable or combustible atmosphere. • Do not open the housing in a flammable or combustible atmosphere. WARNING Area of application This device is suitable for use in environments of Class 1, Division 2, Groups A, B, C, D;...
  • Page 10 Special conditions for safe use of the BusAdapter BusAdapter for Distributed I/O Equipment Manual, 10/2021, A5E39261458-AC...
  • Page 11: Preface

    You can find information about the electrical and optical networks (including cables and cable lengths) in the system manual "SIMATIC NET; Industrial Ethernet / PROFINET; Passive Network Components (https://support.industry.siemens.com/cs/ww/en/view/84922825)". Validity of the documentation This documentation applies to the following products: •...
  • Page 12 • Information about the technical support available can be found in the appendix to this documentation (http://www.siemens.com/simatic-tech-doku-portal). • The technical documentation for the individual SIMATIC products and systems is available on the Internet (https://mall.industry.siemens.com). • The online catalog and the ordering system are available on the Internet (https:// mall.industry.siemens.com).
  • Page 13: Installation

    Installation Connections on the interface module and the BusAdapter Definition The connections on the interface module and BusAdapter connect the respective modules to each other. Description The connections on the interface module and the BusAdapter are shown as follows: Useful information about the interface connection for communication Installing a PROFINET cable on the BusAdapter Depending on the configuration of the PROFINET IO system, you select electrical or optical...
  • Page 14: Examples For The Number Of Media Interfaces

    Installation 4.3 Examples for the number of media interfaces The type of connecting cable determines the BusAdapter required for connecting the distributed I/O. Note Strain relief of the bus cables Make sure to secure the bus cables by installing an appropriate strain relief. Refer to the installation guidelines of the manufacturer.
  • Page 15: Busadapter Ba 2Xfc

    Installation 4.4 BusAdapter BA 2xFC BusAdapter BA 2xFC 4.4.1 Basics of BusAdapter BA 2xFC Definition You connect the IO device to the PROFINET IO system via the BusAdapter BA 2×FC with FastConnect cables. Description The BusAdapter BA 2xFC is designed as follows: ①...
  • Page 16: Stripping Off The Jacket Of The Profinet Connecting Cable

    Installation 4.4 BusAdapter BA 2xFC Note The figure below is a basic representation using the ET 200SP HA as an example; it is also valid for other distributed I/O devices. The mounted BusAdapter BA 2xFC appears as follows: ① BusAdapter BA 2×FC ②...
  • Page 17 Installation 4.4 BusAdapter BA 2xFC Required accessories • Industrial Ethernet Fast Connect Stripping Tool (6GK1901‑1GA00) with green blade cassette (6GK1901‑1B...) for Fast Connect cable • FastConnect cables (recommended types): – IE FC TP Standard Cable GP 2x2 (6XV1840-2AH10) – IE FC TP Trailing Cable 2x2 (6XV1840-3AH10) –...
  • Page 18: Connecting The Cable To The Busadapter

    Installation 4.4 BusAdapter BA 2xFC 4.4.3 Connecting the cable to the BusAdapter Requirement • The BusAdapter BA 2xFC is detached from the I/O. • The jacket of the PROFINET connecting cable is stripped. Procedure 1. Push back the locking slide. ①...
  • Page 19 Installation 4.4 BusAdapter BA 2xFC 4. Insert the insulated single wires of the PROFINET IO cable (according to the printed color coding) all the way into the wire guide. 5. Lay the cable shield on the shield contact. ③ Shield contact ④...
  • Page 20: Mounting A Busadapter

    Installation 4.4 BusAdapter BA 2xFC 7. Close the cover of the connection element. 8. Slide the locking slide forward until it stops. Result The cables of the BusAdapter are connected. 4.4.4 Mounting a BusAdapter Requirement The cables of the BusAdapter are connected. Procedure 1.
  • Page 21: Busadapter Ba 2Xlc

    Installation 4.5 BusAdapter BA 2xLC Result The BusAdapter is mounted on the distributed I/O. BusAdapter BA 2xLC 4.5.1 Basics of BusAdapter BA 2xLC Definition You connect the IO device to the PROFINET IO system via the BusAdapter BA 2×LC with fiber- optic cables.
  • Page 22 Installation 4.5 BusAdapter BA 2xLC ① LED LK 1 - Status of the Ethernet connection port 1 ② LED LK 2 - Status of the Ethernet connection port 2 ③ Connection diagram for the PROFINET connectors (view from left) ④ Fixing screw ⑤...
  • Page 23: Connecting Profinet Io Via The Busadapter

    Installation 4.5 BusAdapter BA 2xLC 4.5.2 Connecting PROFINET IO via the BusAdapter Requirement • The PROFINET IO cables are assembled (fiber-optic cables are connected to LC connectors). • If the device is the last node of the fiber-optic network, the unused fiber-optic interface is closed with a blanking plug.
  • Page 24: Busadapter Ba 2Xrj45

    Result PROFINET IO is connected to the device via the BusAdapter BA 2xLC. See also SIMATIC NET; Industrial Ethernet / PROFINET; Passive Network Components (https:// support.industry.siemens.com/cs/ww/en/view/84922825) BusAdapter BA 2xRJ45 4.6.1 Basics of BusAdapter BA 2xRJ45 Definition You connect the IO device to the PROFINET IO system via the BusAdapter BA 2×RJ45 with Industrial Ethernet cables.
  • Page 25 Installation 4.6 BusAdapter BA 2xRJ45 Description The BusAdapter BA 2×RJ45 is designed as follows: ① LED LK 1 - Status of the Ethernet connection port 1 ② LED LK 2 - Status of the Ethernet connection port 2 ③ Connection diagram for the PROFINET connectors (view from below) ④...
  • Page 26: Connecting Profinet Io Via The Busadapter

    Installation 4.6 BusAdapter BA 2xRJ45 ① BusAdapter BA 2×RJ45 ② RJ45 connector ③ PROFINET IO cable ④ Interface module When installing in an enclosure, you can use FastConnect cables with the "IE FC RJ45 Plug 180" connector. 4.6.2 Connecting PROFINET IO via the BusAdapter Requirement The cables of the BusAdapter are connected.
  • Page 27: Busadapter Ba Lc/Fc

    Installation 4.7 BusAdapter BA LC/FC See also SIMATIC NET; Industrial Ethernet / PROFINET; Passive Network Components (https:// support.industry.siemens.com/cs/ww/en/view/84922825) BusAdapter BA LC/FC Definition You connect the IO device to the PROFINET IO system via the BusAdapter BA LC/FC. Description The nodes communicate over two ports.
  • Page 28: Busadapter Ba Lc/Rj45

    Installation 4.8 BusAdapter BA LC/RJ45 ① LED LK 1 - Status of the Ethernet connection port 1 ② LED LK 2 - Status of the Ethernet connection port 2 ③ Connection diagram for the PROFINET connectors (view from below) • IO port 1 = LC (optical connection) •...
  • Page 29 Installation 4.8 BusAdapter BA LC/RJ45 ① LED LK 1 - Status of the Ethernet connection port 1 ② LED LK 2 - Status of the Ethernet connection port 2 ③ Connection diagram for the PROFINET connectors (view from below) • IO port 1 = LC (optical connection) •...
  • Page 30: Busadapter 2Xrj45Vd Ha

    Installation 4.9 BusAdapter 2xRJ45VD HA BusAdapter 2xRJ45VD HA Definition You connect the IO device to the PROFINET IO system using a 2-wire system with copper wires via the BA 2xRJ45VD HA BusAdapter. NOTICE Application of the BusAdapter If you want to use this BusAdapter in the system, you need to note the following: •...
  • Page 31 Installation 4.9 BusAdapter 2xRJ45VD HA ① LED LK 1 - Status of the Ethernet connection port 1 ② LED without function ③ LED LK 2 - Status of the Ethernet connection port 2 ④ LED without function ⑤ Connection diagram for the PROFINET connectors (view from below) ⑥...
  • Page 32 Installation 4.9 BusAdapter 2xRJ45VD HA BusAdapter for Distributed I/O Equipment Manual, 10/2021, A5E39261458-AC...
  • Page 33: Behavior Of The Device Name

    Behavior of the device name The device name of the distributed I/O device is saved at the following locations when transferring the device name to the distributed I/O: • In the BusAdapter • In the interface of the distributed I/O device (e.g. interface module or I/O device itself) Note Replacing a BusAdapter (removing/inserting) Removing/inserting the BusAdapter under voltage is prohibited.
  • Page 34 Behavior of the device name BusAdapter for Distributed I/O Equipment Manual, 10/2021, A5E39261458-AC...
  • Page 35: Diagnostics

    Diagnostics Status and error displays Definition The LED displays are status and error indicators. Description The following LEDs are available on the front of the BusAdapter: ① LK1 (Page 35) (green) ② LK2 (Page 35) (green) LED LK Definition The LED LK on the BusAdapter visualizes the status of the Ethernet connection. Note Connection configuration with BusAdapter BA 2xRJ45VD HA for long cable lengths It can take up to 2 minutes to establish a connection with the maximum permissible cable length...
  • Page 36 Diagnostics 6.2 LED LK Description The LK LED indicates the following status: LEDs "LK1" and "LK2" Meaning Solution There is an Ethernet connection between the PROFINET IO interface and a communication partner (for example, an IO controller). There is no Ethernet connection between the PROFINET IO interface Check whether the bus cable and a communication partner (for example IO controller).
  • Page 37: Pin Assignments

    Pin assignments Pin assignment of the RJ45 connection plug The pin assignment of the RJ45 connector is shown as follows: View RJ45‑plug socket Contact assignment TD (Transmit Data +) TD_N (Transmit Data –) RD (Receive Data +) Ground Ground RD_N (Receive Data –) Ground Ground Core pair...
  • Page 38: Pin Assignment Of The Fc Outlet (4-Pin Connector)

    Pin assignments A.3 Pin assignment of the FC outlet (4-pin connector) Note Shield support and lightning protection design If you connect a BA 2xRJ45VD HA BusAdapter to existing PROFIBUS cabling, the same specifications regarding shielding and lightning protection concept apply as for PROFIBUS. Pin assignment of the FC outlet (4-pin connector) The pin assignment of the FC outlet is shown as follows: View of FC outlet...
  • Page 39: Technical Specifications

    Technical specifications Ambient conditions Information on the documentation Note Higher-priority documentation The information for the specific components takes precedence over the information in this documentation. The statements in the product information always takes precedence over all other information. Use in hazardous area Read section "Special conditions for safe use of the BusAdapter (Page 7)".
  • Page 40: Table B-2 Derating When Devices Are Used At An Elevation Above Sea Level

    Technical specifications B.1 Ambient conditions Ambient condi‐ Permissible range Comments tions Concentration of Test: 10 ppm; 4 days • : <0.5 ppm pollutants Test: 1 ppm; 4 days • RH: <60%, no condensation • S: <0.1 ppm • RH: <60%, no condensation ISA-S71.04 severity level G1;...
  • Page 41: Simatic Busadapter Ba 2Xrj45 (6Dl1193-6Ar00-0Aa0)

    Technical specifications B.2 SIMATIC BusAdapter BA 2xRJ45 (6DL1193-6AR00-0AA0) SIMATIC BusAdapter BA 2xRJ45 (6DL1193-6AR00-0AA0) Article number 6DL1193-6AR00-0AA0 General information Product type designation BA 2x RJ45 Interfaces Number of PROFINET interfaces 1; 2 ports (switch) RJ45 Supports protocol for PROFINET IO • Number of RJ45 ports Cable length 100 m...
  • Page 42: Simatic Busadapter Ba Lc/Rj45 (6Dl1193-6Ag20-0Aa0)

    Technical specifications B.3 SIMATIC BusAdapter BA LC/RJ45 (6DL1193-6AG20-0AA0) SIMATIC BusAdapter BA LC/RJ45 (6DL1193-6AG20-0AA0) Article number 6DL1193-6AG20-0AA0 General information Product type designation BA LC/RJ45 Interfaces Number of PROFINET interfaces 1; 2 ports (switch) LC / RJ45 Supports protocol for PROFINET IO •...
  • Page 43: Simatic Busadapter Ba 2Xlc (6Dl1193-6Ag00-0Aa0)

    Technical specifications B.4 SIMATIC BusAdapter BA 2xLC (6DL1193-6AG00-0AA0) SIMATIC BusAdapter BA 2xLC (6DL1193-6AG00-0AA0) Article number 6DL1193-6AG00-0AA0 General information Product type designation BA 2xLC Interfaces Number of PROFINET interfaces 1; 2 ports (switch) LC Multimode Glass Fibre Supports protocol for PROFINET IO •...
  • Page 44: Simatic Busadapter Ba Lc/Fc (6Dl1193-6Ag40-0Aa0)

    Technical specifications B.5 SIMATIC BusAdapter BA LC/FC (6DL1193-6AG40-0AA0) SIMATIC BusAdapter BA LC/FC (6DL1193-6AG40-0AA0) Article number 6DL1193-6AG40-0AA0 General information Product type designation BA LC/FC Interfaces Number of PROFINET interfaces 1; 2 ports (switch) LC / FC Supports protocol for PROFINET IO •...
  • Page 45: Simatic Busadapter Ba 2Xfc (6Dl1193-6Af00-0Aa0)

    Technical specifications B.6 SIMATIC BusAdapter BA 2xFC (6DL1193-6AF00-0AA0) SIMATIC BusAdapter BA 2xFC (6DL1193-6AF00-0AA0) Article number 6DL1193-6AF00-0AA0 General information Product type designation BA 2xFC Interfaces Number of PROFINET interfaces 1; 2 ports (switch) FC Supports protocol for PROFINET IO • Number of FC (FastConnect) connections Cable length 100 m –...
  • Page 46 Technical specifications B.6 SIMATIC BusAdapter BA 2xFC (6DL1193-6AF00-0AA0) BusAdapter for Distributed I/O Equipment Manual, 10/2021, A5E39261458-AC...
  • Page 47: C Contact

    Contact Contact Department Contact Repair service Siemens AG Repair Service Facility Digital Industries Factory Automation Operative Q functions DI FA MF EWA QM 31 Mr. Alexander Luber Werner-von-Siemens-Str. 50 92224 Amberg Germany Tel.: +49 9621 80-3447 Manufacturer Siemens AG Digital Industries...
  • Page 48 Contact C.1 Contact BusAdapter for Distributed I/O Equipment Manual, 10/2021, A5E39261458-AC...

Table of Contents