DO NOT ACCEPT VERBAL APPROVALS, AS THEY ARE NOT VALID. Nexwatch never recommends using the PW-3000 or PW-5000 or related products for use as a primary warning or monitoring sys- tem. Primary warning or monitoring systems should always meet local fire and safety code requirements.
Page 6
This document and the data in it shall not be duplicated, used or disclosed to others for procurement or manufacture, except as authorized by and with the written permission of, NexWatch, Inc. The information contained in this document or in the product itself is considered the exclusive property and trade secrets of NexWatch, Inc.
Customer shall immediately notify Nexwatch in writing of all such claims. Nexwatch shall defend or settle such claims and shall indemnify and hold Customer harmless for any costs or damages including reasonable attorneys’...
All Products sold or licensed by Nexwatch include a warranty reg- istration card which must be completed and returned to Nexwatch by or on behalf of the end user in order for Nexwatch to provide warranty service, repair, credit or exchange. All war-...
OR WARRANTY OF THE DISTRIBUTOR SHALL EXTEND THE LIABILITY OR RESPONSIBILITY OF THE MANUFACTURER BEYOND THE TERMS OF THIS PROVISION. IN NO EVENT SHALL NEXWATCH BE LIABLE FOR ANY RE-PROCUREMENT COSTS, LOSS OF PROFITS, LOSS OF USE, INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES TO ANY PERSON RESULTING FROM THE USE OF NEXWATCH’S PRODUCTS.
PW5K1R1-Reader Interface Installation Guide Reader Interface (PW5K1R1) The PW5K1R1 provides interfacing to a TTL/Wiegand type reader and door hardware as needed, for a single door. The Reader Interface can accept data from a reader with clock/data or Wiegand interface and provides a tri-stated LED control and buzzer control. Two form-C relay outputs may be used for strike control or alarm signaling.
Page 11
Installation Guide PW5K1R1-Reader Interface The following circuit is recommended. Locate the protection circuit that is close to the load and one at the PW5K1R1 (within 12 inches [30cm]), as the effectiveness of the circuit will decrease if it is located far away. TD1118 rev1101...
PW5K1R1-Reader Interface Installation Guide Communication to Controller The Interface communicates to a controller via a half duplex multi- drop RS-485 interface. The total cable length is limited to 4,000 feet (1,200 meters). Shielded cable of 24AWG with characteristic imped- ance of 120 ohm and <13pf/ft capacitance is specified for the RS- 485 interface.
Page 13
Installation Guide PW5K1R1-Reader Interface *WIN-PAK PRO uses the panel address 0 / to equal the software setting of 32. TD1118 rev1101...