socket, because lubricant can protect the socket from dirt & moist.
4.2 Battery & Fuse Replacement:
To avoid any electric shock or personal injury as a result of
incorrect reading, replace batteries once the symbol "
on the LCD.
In the current measurement, if the LCD shows "FUSE" with buzzer
alarm, which means the fuse is burnt, please replace the fuse
immediately. Please use the designated fuse (500mA/250V,
10A/250V quick-break fuse).
To avoid any electric shock or damage to the meter, do not attempt
to clean the inside of the meter. You must disconnect all the lines,
before opening the case or battery cover.
Battery replacement:
Turn off the power of the meter.
Disconnect all the test leads.
Use a screwdriver to remove the battery cover.
Remove the old battery and replace with 1 pc 9 V 6F22 new battery.
Fuse replacement:
Turn off the power of the meter and take out the holster.
Use a screwdriver to remove the cover.
Remove the burnt fuse and replace with the same type of fuse
17